DEVELOPMENT OF A CHEMILUMINESCENCE DETECTOR WITH PHOTODIODE DETECTION FOR FLOW-INJECTION ANALYSIS AND ITS APPLICATION TO L-LACTATE ANALYSIS

被引:26
作者
HEMMI, A
YAGIUDA, K
FUNAZAKI, N
ITO, S
ASANO, Y
IMATO, T
HAYASHI, K
KARUBE, I
机构
[1] DKK CORP,TOKYO 180,JAPAN
[2] KYUSHU UNIV,FAC ENGN,HIGASHI KU,FUKUOKA 812,JAPAN
[3] NICHIREI CORP,CHUO KU,TSUKIJI,TOKYO 104,JAPAN
[4] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
关键词
FLOW INJECTION; CHEMILUMINESCENCE; L-LACTATE;
D O I
10.1016/0003-2670(95)00371-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low cost chemiluminescence detector with a photodiode for flow-injection analysis (FIA) of L-lactate in food was developed for quality control in food industry. In this system, L-lactate is oxidized by the enzymatic reaction with L-lactate oxidase immobilized on the column to produce hydrogen peroxide. Then chemiluminescence caused by mixing hydrogen peroxide with the chemiluminescence reagent was detected by the photodiode. This light intensity was proportional to L-lactate concentration. For detecting weak chemiluminescence efficiently a flow-through cell of the detector was specially designed. A photodiode was used for the purpose of reducing the costs of FIA systems instead of a photomultiplier tube. As a result, a linear working curve was obtained from 10(-7) to 10(-3) mol l(-1) L-lactate concentration. We applied the present system with a photodiode detector for food samples and compared the results with those obtained by the conventional HPLC method. The data obtained by the present FIA method were fairly in good agreement with those obtained by the conventional HPLC method. The correlation factor and regression line between both methods were 0.992 and Y = 1.07X - 0.15, respectively. The present FIA system with the photodiode detector is available as a simple, easy-handling instrument for quality control in food industry.
引用
收藏
页码:323 / 327
页数:5
相关论文
共 8 条
[1]   REAGENTLESS AMPEROMETRIC LACTATE ELECTRODE [J].
DURLIAT, H ;
COMTAT, M .
ANALYTICAL CHEMISTRY, 1980, 52 (13) :2109-2112
[2]  
HAYASHI K, 1990, 59TH SPRING ANN M JA, P111
[3]  
HISHIMOTO M, 1991, FOOD IND SENSORS, P323
[4]   MEASUREMENTS OF LACTATE CONCENTRATION USING LACTATE OXIDASE AND AN ELECTROCHEMICAL OXYGEN SENSOR [J].
MAKOVOS, EB ;
LIU, CC .
BIOTECHNOLOGY AND BIOENGINEERING, 1985, 27 (02) :167-170
[5]   SIMULTANEOUS DETERMINATION OF GLUCOSE, ETHANOL AND LACTATE IN ALCOHOLIC BEVERAGES AND SERUM BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
MATSUBARA, H ;
HAMADA, M ;
UKEDA, H ;
OSAJIMA, Y .
JOURNAL OF BIOTECHNOLOGY, 1990, 14 (01) :115-126
[6]   PHOTODIODE-BASED CHEMILUMINOMETRIC BIOSENSORS FOR HYDROGEN-PEROXIDE AND L-LYSINE [J].
PREUSCHOFF, F ;
SPOHN, U ;
JANASEK, D ;
WEBER, E .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (08) :543-549
[7]   FLOW-INJECTION ANALYSIS FOR L-LACTATE WITH IMMOBILIZED LACTATE-DEHYDROGENASE [J].
YAO, T ;
KOBAYASHI, Y ;
MUSHA, S .
ANALYTICA CHIMICA ACTA, 1982, 138 (JUN) :81-85
[8]  
1991, INTRO ION CHROMATOGR, P20