Passive sampler for chlorinated pesticides in estuarine waters

被引:31
作者
Peterson, SM [1 ]
Apte, SC [1 ]
Batley, GE [1 ]
Coade, G [1 ]
机构
[1] NSW EPA,WATERS & CATCHMENTS BRANCH,BANKSTOWN,NSW 2200,AUSTRALIA
来源
CHEMICAL SPECIATION AND BIOAVAILABILITY | 1995年 / 7卷 / 03期
关键词
sampler; hydrophobic organic contaminants; gas chromatography; chlordane; dieldrin;
D O I
10.1080/09542299.1995.11083249
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Monitoring organic contaminants in the marine environment and identitying their bioconcentration pathways presents great difficulties, as the analytical techniques require preconcentration steps that are time-consuming and tedious. Samplers have been developed that can concentrate extremely low levels of hydrophobic compounds, such as organochlorine pesticides, from water bodies, for direct analysis with minimal sample preparation. The passive samplers consist of polyethylene tubes filled with iso-octane that are deployed within weighted wire cages in estuaries and rivers for a period of three weeks. Hydrophobic compounds such as chlorinated pesticides are continuously partitioned from the water column into the solvent within the tube, providing an integrated sample over the duration of exposure. Pesticides are concentrated 200-300 fold in three weeks. Upon retrieval, the contents can be analysed directly by gas chromatography-electron capture detector (GC-ECD) or concentrated for analysis by gas chromatography-mass spectrometry (GC-MS). Laboratory experiments to determine the uptake rate of the compounds into the sampler enable the calculation of average water concentration over the sampling period. The samplers are cheap and easy to prepare, enabling their deployment in numerous sites over long periods if required. They are envisaged as being a quick and easy monitor for background levels of these contaminants within our waterways.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 10 条
[1]   BIOCONCENTRATION [J].
BARRON, MG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (11) :1612-1618
[2]   INSITU DIALYSIS FOR DETERMINATION OF STATE OF TRACE-ELEMENTS IN NATURAL-WATERS [J].
BENES, P ;
STEINNES, E .
WATER RESEARCH, 1974, 8 (11) :947-953
[3]   COMPLETE ANALYSIS OF TECHNICAL CHLORDANE USING NEGATIVE IONIZATION MASS-SPECTROMETRY [J].
DEARTH, MA ;
HITES, RA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (02) :245-254
[4]   SEMIPERMEABLE-MEMBRANE DEVICES CONTAINING MODEL LIPID - A NEW APPROACH TO MONITORING THE BIOAVAILABILITY OF LIPOPHILIC CONTAMINANTS AND ESTIMATING THEIR BIOCONCENTRATION POTENTIAL [J].
HUCKINS, JN ;
TUBERGEN, MW ;
MANUWEERA, GK .
CHEMOSPHERE, 1990, 20 (05) :533-552
[5]   GEOGRAPHICAL-DISTRIBUTION OF PERSISTENT ORGANOCHLORINES IN AIR, WATER AND SEDIMENTS FROM ASIA AND OCEANIA, AND THEIR IMPLICATIONS FOR GLOBAL REDISTRIBUTION FROM LOWER LATITUDES [J].
IWATA, H ;
TANABE, S ;
SAKAI, N ;
NISHIMURA, A ;
TATSUKAWA, R .
ENVIRONMENTAL POLLUTION, 1994, 85 (01) :15-33
[6]   HEXANE-FILLED DIALYSIS BAGS FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
JOHNSON, GD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (11) :1897-1903
[7]   APPLICATION OF PASSIVE SAMPLERS (PISCES) TO LOCATING A SOURCE OF PCBS ON THE BLACK RIVER, NEW-YORK [J].
LITTEN, S ;
MEAD, B ;
HASSETT, J .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1993, 12 (04) :639-647
[8]  
SODERGREN A, 1987, ENVIRON SCI TECHNOL, V21, P855
[9]  
ZABIK JM, 1992, ENVIRON TOXICOL CHEM, V11, P765, DOI 10.1897/1552-8618(1992)11[765:RCOPRI]2.0.CO
[10]  
2