PULSE OXIMETER PROBES - A COMPARISON BETWEEN FINGER, NOSE, EAR AND FOREHEAD PROBES UNDER CONDITIONS OF POOR PERFUSION

被引:59
作者
CLAYTON, DG [1 ]
WEBB, RK [1 ]
RALSTON, AC [1 ]
DUTHIE, D [1 ]
RUNCIMAN, WB [1 ]
机构
[1] ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERRACE,ADELAIDE,SA 5000,AUSTRALIA
关键词
EQUIPMENT; PULSE OXIMETERS; MEASUREMENT;
D O I
10.1111/j.1365-2044.1991.tb11492.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The performances of 10 pulse oximeters using finger probes were compared with the same pulse oximeters using alternative probes (eight finger probes, two nose probes and a forehead probe) in poorly perfused patients. All readings were then compared with directly measured arterial blood oxygen saturations. The mean difference (bias, ‘accuracy’), standard deviation (precision) and ‘drop out’ rate for each pulse oximeter combination was determined. An overall ranking of performance of each pulse oximeter was calculated using five criteria (accuracy, precision, number of readings within 3% of standard, percentage of readings given within 3% of standard, expected overread limit in 95% of cases). Nose and forehead probes performed poorly. Some ear probes performed well compared to some finger probes, but the overall performance of probes in other sites compared to finger probes was worse, (p = 0.05). Two of eight ear probes and no nose or forehead probes would be expected to be within 4% of the reference value in 95% of readings. The use of finger probes rather than probes in other sites is recommended in the patient with poor peripheral perfusion. Copyright © 1991, Wiley Blackwell. All rights reserved
引用
收藏
页码:260 / 265
页数:6
相关论文
共 13 条
[1]  
ALEXANDER CM, 1989, ANESTH ANALG, V68, P368
[2]   A COMPARISON OF THE PERFORMANCE OF 20 PULSE OXIMETERS UNDER CONDITIONS OF POOR PERFUSION [J].
CLAYTON, DG ;
WEBB, RK ;
RALSTON, AC ;
DUTHIE, D ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (01) :3-10
[3]   EVALUATION OF THE OHMEDA 3700 PULSE OXIMETER - STEADY-STATE AND TRANSIENT-RESPONSE CHARACTERISTICS [J].
KAGLE, DM ;
ALEXANDER, CM ;
BERKO, RS ;
GIUFFRE, M ;
GROSS, JB .
ANESTHESIOLOGY, 1987, 66 (03) :376-380
[4]   PULSE OXIMETRY [J].
KELLEHER, JF .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (01) :37-62
[5]   PERIPHERAL PERFUSION AFTER CARDIAC-SURGERY [J].
KUTTILA, K ;
NIINIKOSKI, J .
CRITICAL CARE MEDICINE, 1989, 17 (03) :217-220
[6]   NONINVASIVE DETECTION OF PROFOUND ARTERIAL DESATURATIONS USING A PULSE OXIMETRY DEVICE [J].
MIHM, FG ;
HALPERIN, BD .
ANESTHESIOLOGY, 1985, 62 (01) :85-87
[7]   A COMPARISON OF 15 PULSE OXIMETERS .1. A CLINICAL COMPARISON .2. A TEST OF PERFORMANCE UNDER CONDITIONS OF POOR PERFUSION [J].
MORRIS, RW ;
NAIRN, M ;
TORDA, TA .
ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (01) :62-73
[8]  
PALVE H, 1989, CRIT CARE MED, V17, P66
[9]   ACCURACY OF RESPONSE OF 6 PULSE OXIMETERS TO PROFOUND HYPOXIA [J].
SEVERINGHAUS, JW ;
NAIFEH, KH .
ANESTHESIOLOGY, 1987, 67 (04) :551-558
[10]  
TREMPER KK, 1989, ANESTHESIOLOGY, V70, P98, DOI 10.1097/00000542-198901000-00019