PREDICTION OF FUNCTIONAL AEROBIC CAPACITY WITHOUT EXERCISE TESTING

被引:505
作者
JACKSON, AS [1 ]
BLAIR, SN [1 ]
MAHAR, MT [1 ]
WIER, LT [1 ]
ROSS, RM [1 ]
STUTEVILLE, JE [1 ]
机构
[1] NASA, LYNDON B JOHNSON SPACE CTR, CARDIOPULM LAB, HOUSTON, TX 77058 USA
关键词
Estimating aerobic capacity; Multiple regression; Physical activity assessment; Submaximal exercise testing;
D O I
10.1249/00005768-199012000-00021
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to develop functional aerobic capacity prediction models without using exercise tests (N-Ex) and to compare the accuracy with Astrand single-stage submaximal prediction methods. The data of 2,009 subjects (9.7% female) were randomly divided into validation (N = 1,543) and cross-validation (N = 466) samples. The validation sample was used to develop two N-Ex models to estimate VO2peak. Gender, age, body composition, and self-report activity were used to develop two N-Ex prediction models. One model estimated percent fat from skinfolds (N-Ex %fat) and the other used body mass index (N-Ex BMI) to represent body composition. The multiple correlations for the developed models were R = 0.81 (SE = 5.3 ml·kg-1·min-1) and R = 0.78 (SE = 5.6 ml·kg-1·min-1). This accuracy was confirmed when applied to the cross-validation sample. The N-Ex models were more accurate than what was obtained from VO2peak estimated from the Astrand prediction models. The SEs of the Astrand models ranged from 5.5-9.7 ml·kg-1·min-1. The N-Ex models were cross-validated on 59 men on hypertensive medication and 71 men who were found to have a positive exercise ECG. The SEs of the N-Ex models ranged from 4.6-5.4 ml·kg-1·min-1 with these subjects. An analysis of subsamples of the cross-validation sample showed that the accuracy of the models was upheld with all but subjects with a VO2peak≥55 ml·kg-1·min-1. this confirmed that the N-Ex models were more accurate than established submaximal treadmill prediction models and are appropriate for about 96% of the adult population. © 1990 by the American College of Sports Medicine.
引用
收藏
页码:863 / 870
页数:8
相关论文
共 35 条
  • [1] ASTRAND I, 1960, Acta Physiol Scand Suppl, V49, P1
  • [2] ASTRAND PO, 1986, TXB WORK PHYSL, P318
  • [3] MAXIMAL OXYGEN INTAKE AND NOMOGRAPHIC ASSESSMENT OF FUNCTIONAL AEROBIC IMPAIRMENT IN CARDIOVASCULAR DISEASE
    BRUCE, RA
    KUSUMI, F
    HOSMER, D
    [J]. AMERICAN HEART JOURNAL, 1973, 85 (04) : 546 - 562
  • [4] Cink R E, 1981, Br J Sports Med, V15, P182
  • [5] DeVries H A, 1965, J Sports Med Phys Fitness, V5, P207
  • [6] FOSTER C, 1984, AM HEART J, V107, P1229, DOI 10.1016/0002-8703(84)90282-5
  • [7] COMPARISON OF MAXIMAL OXYGEN UPTAKE VALUES DETERMINED BY PREDICTED AND ACTUAL METHODS
    GLASSFORD, RG
    BAYCROFT, GH
    SEDGWICK, AW
    MACNAB, RBJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (03) : 509 - +
  • [8] Golding L., 1989, YS WAY PHYS FITNESS, P89
  • [9] HASKELL WL, 1982, AM J CARDIOL, V50, P299, DOI 10.1016/0002-9149(82)90180-1
  • [10] Jackson A.S., 1989, MEASUREMENT CONCEPTS, P181