A COMPARISON OF THE FILTRATION PROPERTIES OF HEAT AND MOISTURE EXCHANGERS

被引:57
作者
HEDLEY, RM [1 ]
ALLTGRAHAM, J [1 ]
机构
[1] ST GEORGE HOSP,DEPT ANAESTHESIA,LONDON SW17 0QT,ENGLAND
关键词
EQUIPMENT; HEAT AND MOISTURE EXCHANGERS; BACTERIAL FILTERS;
D O I
10.1111/j.1365-2044.1992.tb02225.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Heat and Moisture Exchangers are used increasingly as filters to prevent the contamination of breathing apparatus and to limit cross‐infection. A series of laboratory tests has been developed to evaluate the microbial filtration and air flow resistance properties of these devices. The tests were designed to simulate the clinical situation and therefore evaluated devices in both dry and wet conditions. The devices tested (Engstrom Edith, Pall BB50T, Dar Hygrobac, Intersurgical Filtatherm and Intersurgical Filtaguard) were each representative of a particular type of construction. The simple hygroscopic device (Engstrom Edith) showed poor airborne and liquid‐borne filtration efficiency, but its resistance to air flow remained low in all conditions. The composite devices (Dar Hygrobac, Intersurgical Filtatherm and Intersurgical Filtaguard), which all possessed relatively large pores, performed well in terms of dry airborne filtration efficiency, but showed substantial increases in airflow resistance and poor filtration efficiency in the presence of liquid. The pleated membrane filter (Pall BB50T), which possessed small pores, showed good airborne filtration efficiency and prevented the passage of liquid. The latter property enabled this device to prevent the passage of liquid‐borne contamination and to maintain a low resistance to airflow in wet conditions. It would appear that in terms of contamination control and air flow resistance the pleated membrane filter provides a wider margin of safety than either the hygroscopic or composite devices. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:414 / 420
页数:7
相关论文
共 14 条
[1]  
BETHUNE DW, 1989, JUN P EUR ASS CARD A
[2]  
CHALON J, 1984, ANESTH ANALG, V63, P566
[3]  
Duberstein R, 1978, J Parenter Drug Assoc, V32, P192
[4]   CONTAMINATION CONTROL IN LONG-TERM VENTILATION - A CLINICAL-STUDY USING A HEAT-EXCHANGING AND MOISTURE-EXCHANGING FILTER [J].
GALLAGHER, J ;
STRANGEWAYS, JEM ;
ALLTGRAHAM, J .
ANAESTHESIA, 1987, 42 (05) :476-481
[5]   HYGROSCOPIC CONDENSER HUMIDIFIER - NEW DEVICE FOR GENERAL USE IN ANESTHESIA AND INTENSIVE-CARE [J].
GEDEON, A ;
MEBIUS, C .
ANAESTHESIA, 1979, 34 (10) :1043-1047
[6]   HYGROSCOPIC CONDENSER HUMIDIFIERS - VALUE FOR MONEY [J].
GILSTON, A .
ANAESTHESIA, 1984, 39 (10) :1030-1031
[7]   A NEW CONDENSER HUMIDIFIER [J].
LEIGH, JM ;
WHITE, MG .
ANAESTHESIA, 1984, 39 (05) :492-493
[8]  
MIROINI T, 1990, KRANKENHAUS HYGIENE, V12, P24
[9]   COMPLICATIONS RELATED TO THE USE OF A HEAT AND MOISTURE EXCHANGER [J].
PRASAD, KK ;
CHEN, L .
ANESTHESIOLOGY, 1990, 72 (05) :958-958
[10]  
SANGE K, 1980, ACTA ANAESTH SCAND, V24, P487