BIOMECHANICAL ANALYSIS OF PATELLAR TENDON ALLOGRAFTS AS A FUNCTION OF DONOR AGE

被引:68
作者
FLAHIFF, CM [1 ]
BROOKS, AT [1 ]
HOLLIS, M [1 ]
VANDERSCHILDEN, JL [1 ]
NICHOLAS, RW [1 ]
机构
[1] UNIV ARKANSAS MED SCI HOSP,DEPT ORTHOPAED SURG,LITTLE ROCK,AR 72205
关键词
D O I
10.1177/036354659502300319
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated the biomechanical properties of patellar tendon allografts from donors aged 18 to 55 years, Bone-patellar tendon-bone complexes were harvested from acceptable donors and processed. Fat and soft tissue were removed, and the tendons were sectioned lengthwise leaving the central third. Area measurements were taken, and mechanical testing was performed. Specimens were pulled to failure at a rate of 10% of the initial length per second, The force at failure, tensile stress, modulus of elasticity, and percent elongation were determined for each specimen, There was no significant correlation (P > 0.05) between age and any of the mechanical properties. Load at failure ranged from 2110 to 4650 N, with a mean of 3424 N. Regression analysis showed slightly decreasing tensile stress with increasing age, but the correlation was not significant. It appears that patellar tendon allografts from donors up to age 55 have similar mechanical properties.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 24 条
[1]  
Blevins F.T., Hecker A.T., Bigler G.T., Et al., Am J Sports Med, 22, pp. 328-333, (1994)
[2]  
Bonamo J.J., Krinick R.M., J Bone Joint Surg, 66A, pp. 1294-1297, (1984)
[3]  
Butler D.L., Kay M.D., Biomechanics, 19, pp. 425-432, (1986)
[4]  
pp. 193-210, (1987)
[5]  
Cooper D.E., Deng X.H., Burstein A.L., Et al., Am J Sports Med, 21, pp. 818-824, (1993)
[6]  
DeLee J.C., Am J Sports Med, 19, pp. 415-416, (1991)
[7]  
Fetto J.F., Clin Orthop, 147, pp. 29-38, (1980)
[8]  
Fu F.H., Jackson D.W., Jamison J., Et al., pp. 325-338, (1993)
[9]  
Haut R.C., Adv in Bioeng, 8, pp. 75-78, (1988)
[10]  
Hubbard R.P., J Biomed Eng, 106, pp. 144-150, (1984)