ONLINE FLUORESCENCE LIFETIME DETECTION FOR CHROMATOGRAPHIC PEAK RESOLUTION

被引:18
作者
COBB, WT [1 ]
MCGOWN, LB [1 ]
机构
[1] DUKE UNIV,DEPT CHEM,PM GROSS CHEM LAB,DURHAM,NC 27706
关键词
D O I
10.1021/ac00201a019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Frequency-domain fluorescence lifetime measurements, made on-the-fly during high-performance liquid chromatography, were used to resolve overlapping chromatographic peaks of polycyclic aromatic hydrocarbons. Two-component heterogeneity analysis of the multifrequency lifetime data provided fractional intensity contributions for the individual components, which were multiplied by the total fluorescence intensity to yield the peaks of each component. Excellent results were obtained when the fluorescence lifetimes of the components were fixed In the heterogeneity analysis to values obtained from the on-the-fly lifetime chromatograms. Positive errors in the peak intensities were observed when the lifetimes were allowed to float in the heterogeneity analysis; the source of the error has not yet been identified but may be due to systematic bias in the heterogeneity analysis software. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:186 / 189
页数:4
相关论文
共 8 条
[1]   MULTIFREQUENCY PHASE-MODULATION FLUORESCENCE LIFETIME DETERMINATIONS ON-THE-FLY IN HPLC [J].
COBB, WT ;
MCGOWN, LB .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1363-1367
[2]   PHASE-MODULATION FLUOROMETRY FOR ONLINE LIQUID-CHROMATOGRAPHIC DETECTION AND ANALYSIS OF MIXTURES OF BENZO(K)FLUORANTHENE AND BENZO(B)FLUORANTHENE [J].
COBB, WT ;
MCGOWN, LB .
APPLIED SPECTROSCOPY, 1987, 41 (08) :1275-1279
[3]   MEASUREMENT OF FLUORESCENCE LIFETIMES DURING LIQUID-CHROMATOGRAPHY [J].
DESILETS, DJ ;
KISSINGER, PT ;
LYTLE, FE .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1830-1834
[4]   TIME-RESOLVED FLUOROMETRY IN DETECTION OF ULTRATRACE POLYCYCLIC AROMATIC-HYDROCARBONS IN LAKE WATERS BY LIQUID-CHROMATOGRAPHY [J].
FURUTA, N ;
OTSUKI, A .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2407-2413
[5]   TIME-RESOLVED FLUORIMETRY WITH A SUBNANOSECOND DYE-LASER SOURCE FOR THE DETERMINATION OF POLYNUCLEAR AROMATIC-HYDROCARBONS AFTER SEPARATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMASAKA, T ;
ISHIBASHI, K ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1982, 142 (OCT) :1-12
[6]   TRACE DETERMINATION AND CHARACTERIZATION OF SOME PROTEINS IN BLOOD-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A TIME-RESOLVED LASER FLUORIMETRIC DETECTOR [J].
KAWABATA, Y ;
SAUDA, K ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) :255-262
[7]  
Lakowicz JR., 2006, PRINCIPLES FLUORESCE
[8]   TIME-RESOLVED LASER-INDUCED FLUORESCENCE WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBON MIXTURES [J].
RICHARDSON, JH ;
LARSON, KM ;
HAUGEN, GR ;
JOHNSON, DC ;
CLARKSON, JE .
ANALYTICA CHIMICA ACTA, 1980, 116 (02) :407-411