REDUCTION OF INJECTION VARIANCE IN FLOW-INJECTION ANALYSIS

被引:8
作者
JOHNSON, BF [1 ]
MALICK, RE [1 ]
DORSEY, JG [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
D O I
10.1016/0039-9140(92)80047-H
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to achieve maximum sensitivity in flow-injection analysis, sample dispersion must be kept to a minimum. This dispersion process, however, is not well understood. Studies of the dispersion process have concentrated on dispersion within the flow manifold while dispersion due to the injection process has been largely ignored. Here sample injection loops packed with inert glass beads and a Serpentine II (distorted) empty loop were constructed and compared to traditional empty sample loops. Digitization of the response curves and subsequent calculation of the statistical moments were used to compare the contribution of each sample loop type to the total system dispersion. Both packed and Serpentine II sample loops were shown to decrease dispersion and increase throughput in flow-injection systems. Plots of peak variance vs. injection volume show variance increasing 1.67 times faster with traditional open sample loops compared to packed loops. When combined with other peak width minimization techniques, this method should further lower concentration limits of detection.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 23 条
[1]   EFFECT OF BASELINE ERRORS ON THE CALCULATION OF STATISTICAL MOMENTS OF TAILED CHROMATOGRAPHIC PEAKS [J].
ANDERSON, DJ ;
WALTERS, RR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :353-359
[2]   DISPERSION COEFFICIENT AND MOMENT ANALYSIS OF FLOW-INJECTION ANALYSIS PEAKS [J].
BROOKS, SH ;
LEFF, DV ;
TORRES, MAH ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2737-2744
[3]   MOMENT ANALYSIS FOR EVALUATION OF FLOW-INJECTION MANIFOLDS [J].
BROOKS, SH ;
DORSEY, JG .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :35-46
[4]   EFFECT OF PEAK SENSING AND RANDOM NOISE ON PRECISION AND ACCURACY OF STATISTICAL MOMENT ANALYSES FROM DIGITAL CHROMATOGRAPHIC DATA [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :1922-&
[5]  
COQ B, 1981, J CHROMATOGR SCI, V19, P1
[6]  
CURTIS MA, 1988, LC GC-MAG SEP SCI, V6, P158
[7]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[8]   COMPUTER CHARACTERIZATION OF CHROMATOGRAPHIC PEAKS BY PLATE HEIGHT AND HIGHER CENTRAL MOMENTS [J].
GRUSHKA, E ;
MYERS, MN ;
SCHETTLER, PD ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1969, 41 (07) :889-+
[9]   CHEMICAL-KINETICS WITH REAGENT DISPERSION IN SINGLE-LINE FLOW-INJECTION SYSTEMS [J].
HUNGERFORD, JM ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :1-19
[10]   REVIEW OF THE EXPONENTIALLY MODIFIED GAUSSIAN (EMG) FUNCTION SINCE 1983 [J].
JEANSONNE, MS ;
FOLEY, JP .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :258-266