DETERMINATION OF CARBARYL IN PESTICIDE FORMULATIONS BY FOURIER-TRANSFORM INFRARED SPECTROMETRY WITH FLOW-ANALYSIS

被引:22
作者
GALLIGNANI, M [1 ]
GARRIGUES, S [1 ]
MARTINEZVADO, A [1 ]
DELAGUARDIA, M [1 ]
机构
[1] UNIV VALENCIA,DEPT ANALYT CHEM,50 DR MOLINER ST,E-46100 BURJASSOT,SPAIN
关键词
FOURIER TRANSFORM INFRARED SPECTROMETRY; FLOW ANALYSIS; CARBARYL; 1-NAPHTHYL METHYLCARBAMATE; PESTICIDE FORMULATION;
D O I
10.1039/an9931801043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure is proposed for the Fourier transform infrared spectrometric determination of carbaryl in pesticide formulations. The method is based in the dissolution of carbaryl in dichloromethane from solid powdered samples and direct measurement of the absorbance at 1747 cm-1 using a spectral baseline established from 1850 to 1650 cm-1. Absorbance measurements can be carried out in the continuous-flow or stopped-flow mode. In both instances the method provides accurate and reproducible results but the stopped-flow mode is the more sensitive. Under the optimum experimental conditions, for an optical pathlength of 1.0 mm and using five accumulated scans, the limit of detection obtained in the stopped-flow mode corresponds to 1.6 mug ml-1 of carbaryl. Real samples of powdered pesticide formulations containing carbaryl were analysed by the proposed procedure and the results were compared with those obtained by a reference spectrofluorimetric procedure.
引用
收藏
页码:1043 / 1048
页数:6
相关论文
共 39 条
[1]  
ALLIGNANI M, 1993, ANAL CHIM ACTA, V274, P267
[2]  
APPAIAH KM, 1982, J ASSOC OFF ANA CHEM, V65, P32
[3]  
ARGANER RJ, 1980, PESTICIDES ANAL METH
[4]   ROOM-TEMPERATURE PHOSPHORIMETRY OF CARBARYL IN LOW-BACKGROUND PAPER [J].
CAMPIGLIA, AD ;
DELIMA, CG .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2822-2827
[5]   DETERMINATION OF PHENYL ISOCYANATE IN A FLOW-INJECTION SYSTEM WITH INFRARED SPECTROMETRIC DETECTION [J].
CURRAN, DJ ;
COLLIER, WG .
ANALYTICA CHIMICA ACTA, 1985, 177 :259-262
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CARBARYL AND 1-NAPHTHOL IN BIOLOGICAL-FLUIDS [J].
DEBERARDINIS, M ;
WARGIN, WA .
JOURNAL OF CHROMATOGRAPHY, 1982, 246 (01) :89-94
[7]   FLOW-INJECTION FOURIER-TRANSFORM INFRARED SPECTROMETRIC ANALYSIS [J].
DELAGUARDIA, M ;
GARRIGUES, S ;
GALLIGNANI, M ;
BURGUERA, JL ;
BURGUERA, M .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :53-57
[8]  
ERNST GF, 1975, J ASSOC OFF ANA CHEM, V58, P1015
[9]   FEASIBILITY STUDY OF CONSTANT ENERGY SYNCHRONOUS LUMINESCENCE SPECTROMETRY FOR PESTICIDE DETERMINATION - APPLICATION TO CARBARYL, NAPHTHOL, AND CARBOFURAN [J].
FILES, LA ;
WINEFORDNER, JD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1987, 35 (04) :471-474
[10]   A NEW SAMPLING TECHNIQUE FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
FUJIMOTO, C ;
OOSUKA, T ;
JINNO, K .
ANALYTICA CHIMICA ACTA, 1985, 178 (02) :159-167