ATROPHY OF THE PROXIMAL PART OF THE FEMUR AFTER TOTAL HIP-ARTHROPLASTY WITHOUT CEMENT - A QUANTITATIVE COMPARISON OF COBALT-CHROMIUM AND TITANIUM FEMORAL STEMS WITH USE OF DUAL X-RAY ABSORPTIOMETRY

被引:45
作者
HUGHES, SS [1 ]
FURIA, JP [1 ]
SMITH, P [1 ]
PELLEGRINI, VD [1 ]
机构
[1] UNIV ROCHESTER, DEPT ORTHOPAED, ROCHESTER, NY USA
关键词
D O I
10.2106/00004623-199502000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare the density of periprosthetic bone about titanium and cobalt-chromium stems that had been inserted without cement. The analysis was done, three to four years after a total hip arthroplasty, in a retrospectively matched cohort of thirty patients. Fifteen patients had a stem that was collarless, proximally coated, and made of titanium; the other fifteen had a stem of similar design that was made of cobalt-chromium. The criteria for selection in the study included an excellent clinical and radiographic result and separately calculated modified Harris and Mayo hip scores of more than 94 points. All stems had radiographic evidence of osseous ingrowth. A comparison of the bone-mineral density about the two different types of stem with dual-energy x-ray absorptiometry revealed a significant difference only along the calcar of the femur. There was no significant difference about the remaining, preponderant portion of the proximal part of the femur. Our data suggest that the difference in the modulus of elasticity between the two types of stem had little effect on the loss of bone-mineral density in most of the proximal part of the femur after arthroplasty without cement.
引用
收藏
页码:231 / 239
页数:9
相关论文
共 44 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
ANDREW TA, 1986, CLIN ORTHOP RELAT R, V206, P127
[4]  
BELL AL, 1989, CLIN ORTHOP RELAT R, P194
[5]  
BOBYN JD, 1990, CLIN ORTHOP RELAT R, V261, P196
[6]   OSTEOLYTIC CHANGES IN THE UPPER FEMORAL-SHAFT FOLLOWING POROUS-COATED HIP-REPLACEMENT [J].
BROWN, IW ;
RING, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :218-221
[7]   LOCALIZED BONE-RESORPTION IN THE FEMUR IN MECHANICAL FAILURE OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
CARLSSON, AS ;
GENTZ, CF ;
LINDER, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (03) :396-402
[8]   INFLUENCE OF DESIGN PARAMETERS ON CALCAR STRESSES FOLLOWING FEMORAL-HEAD ARTHROPLASTY [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (02) :133-143
[9]  
Diegel P D, 1989, J Arthroplasty, V4, P173, DOI 10.1016/S0883-5403(89)80071-3
[10]   EFFECT OF FEMORAL COMPONENT SECTION MODULUS ON THE STRESS-DISTRIBUTION IN THE PROXIMAL HUMAN FEMUR [J].
ENGELHARDT, JA ;
SAHA, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (01) :38-45