Heart rate and blood pressure were measured in lightly anesthetized developing Xenopus laevis from hatching (body mass similar to 3 mg) to the end of metamorphosis (less than or equal to 1 g). Blood pressures in the conus arteriosus, truncus arteriosus, and ventricle were measured by a servo-null micropressure system. Heart rate was determined from blood pressure recordings, and cardiac cycles were videotaped through a dissecting microscope. Heart rate varied from 50 to 150 beats/min and showed a negative correlation with body mass, with a slope less than predicted from allometric equations based on adult vertebrates. Mean truncus pressures showed a positive correlation with body mass, increasing from 4 mmHg in a 25-mg larva to 9 mmHg in a 1-g larva. The pressure waveform during ventricular systole was similar in all developmental stages examined, whereas those in conus and truncus varied with development. Conus pressures differed distinctly from truncus pressure during diastole in all larvae examined, suggesting the existence of functional valves between conus and truncus as early as stage 46 of the Nieuwkoop-Faber larval staging system. Although the developmental patterns of heart rate and blood pressure in X. laevis showed significant correlation with body mass, body mass explained less than one-half of the variation in these variables. Therefore developmental factors other than body mass, such as changes in heart mass and the addition of new resistance vessels, may influence heart rate and blood pressure during development in X. laevis.