PERIPHERALLY INSERTED CENTRAL CATHETERS IN AN ACUTE-CARE HOSPITAL

被引:71
作者
LAM, S
SCANNELL, R
ROESSLER, D
SMITH, MA
机构
[1] ALBERT EINSTEIN COLL MED,LONG ISL JEWISH MED CTR,DEPT MED,DIV INFECT DIS,NEW HYDE PK,NY 11042
[2] ALBERT EINSTEIN COLL MED,LONG ISL JEWISH MED CTR,DEPT NURSING,NEW HYDE PK,NY 11040
关键词
D O I
10.1001/archinte.154.16.1833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Peripherally inserted central catheterization is a relatively new approach for intravenous therapy in acute-care hospitals. Few studies are available on peripherally inserted central catheters (PICCs) used in adult patients in an acute-care setting. We examine the natural history and outcome of PICC use in our hospital. Methods: A retrospective review was undertaken of all hospitalized patients who had PICCs inserted in an acute-care, metropolitan teaching hospital for any reason from July 1991 through July 1992. Patients who had PICCs inserted, used, and then removed in the same hospitalization were evaluated. Results: A total of 135 PICCs were inserted in 114 patients. Six PICCs (4.4%) were inserted in intensive care unit settings and 129 (95.6%) in general medical or surgical service. The mean duration,catheters were in place before removal was 14.1 days. Sixty-three catheters (46.7%) were removed following completion of therapy. The rate of PICC-related infection was 2.2% (three catheters). The occlusion rate was higher for 20-gauge catheters (18.4%) than for 18-gauge catheters (8.2%) (P=.08). When the rate of complications was compared as a function of catheter use (total parenteral nutrition vs any other use), there was no statistically significant difference (P=.12). Overall complications related to catheter insertion and removal were uncommon. Conclusions: Based on our study, we conclude that the PICC provides a reasonable and safe alternative to other centrally placed venous devices. In addition, the convenience of maintaining a PICC compared with peripheral intravenous access makes this an attractive method for in-hospital use.
引用
收藏
页码:1833 / 1837
页数:5
相关论文
共 25 条
  • [1] PROSPECTIVE-STUDY OF CATHETER REPLACEMENT AND OTHER RISK-FACTORS FOR INFECTION OF HYPERALIMENTATION CATHETERS
    ARMSTRONG, CW
    MAYHALL, CG
    MILLER, KB
    NEWSOME, HH
    SUGERMAN, HJ
    DALTON, HP
    HALL, GO
    GENNINGS, C
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1986, 154 (05) : 808 - 816
  • [2] BAGNALL HA, 1989, PEDIATRICS, V83, P963
  • [3] BENEZRA D, 1988, AM J MED, V85, P495
  • [4] BOTTINO J, 1979, CANCER, V43, P1937, DOI 10.1002/1097-0142(197905)43:5<1937::AID-CNCR2820430554>3.0.CO
  • [5] 2-T
  • [6] Brown J M, 1989, J Intraven Nurs, V12, P144
  • [7] DETRICH KA, 1988, PEDIATR PULM, V4, P181
  • [8] CENTRAL VS PERIPHERAL VENOUS CATHETERS IN CRITICALLY ILL PATIENTS
    GIUFFRIDA, DJ
    BRYANBROWN, CW
    LUMB, PD
    KWUN, KB
    RHOADES, HM
    [J]. CHEST, 1986, 90 (06) : 806 - 809
  • [9] Goodwin M L, 1989, J Intraven Nurs, V12, P238
  • [10] CENTRAL CATHETER INFECTIONS - SINGLE-LUMEN VERSUS TRIPLE-LUMEN CATHETERS - INFLUENCE OF GUIDE WIRES ON INFECTION-RATES WHEN USED FOR REPLACEMENT OF CATHETERS
    HILTON, E
    HASLETT, TM
    BORENSTEIN, MT
    TUCCI, V
    ISENBERG, HD
    SINGER, C
    [J]. AMERICAN JOURNAL OF MEDICINE, 1988, 84 (04) : 667 - 672