EORTC JOINT VENTURES IN QUALITY-CONTROL - TREATMENT-RELATED VARIABLES AND DATA ACQUISITION IN CHEMOTHERAPY TRIALS

被引:34
作者
VANTONGELEN, K
STEWARD, W
BLACKLEDGE, G
VERWEIJ, J
VANOOSTEROM, A
机构
[1] WESTERN INFIRM & ASSOCIATED HOSP, BEATSON ONCOL CTR, GLASGOW G11 6NT, SCOTLAND
[2] QUEEN ELIZABETH HOSP, BIRMINGHAM B15 2TH, W MIDLANDS, ENGLAND
[3] DR DANIEL DENHOED CANC CTR, ROTTERDAM, NETHERLANDS
[4] UNIV HOSP ANTWERP, DEPT ONCOL, EDEGEM, BELGIUM
关键词
D O I
10.1016/0277-5379(91)90488-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In multicentre studies, non-compliance with the protocol may limit the chances of reaching a correct conclusion. A procedure to examine the administration of chemotherapy in multicentre EORTC protocols has been developed. General aspects are covered in a mailed questionnaire on the prescription of drugs with rounding up or down of dosages, local facilities for preparation and the procedure for preparation and administration. More detail is collected during a quality control site visit. Ten centres have been visited and there was significant variation between centres in the organisation of chemotherapy administration. However, more striking differences were noted between the type and quality of hospital files. The lack of systematic recording of sequence, timing and doses of chemotherapy and, in particular, treatment related toxicity, is a major difficulty limiting the effectiveness of quality control. These shortcomings emphasise the need for standardisation of some aspects of case records and a suggested check-list has been drafted.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 13 条
[1]  
ARRIAGADA R, 1989, B CANCER, V76, P605
[2]   DOSE - A CRITICAL FACTOR IN CANCER-CHEMOTHERAPY [J].
FREI, E ;
CANELLOS, GP .
AMERICAN JOURNAL OF MEDICINE, 1980, 69 (04) :585-594
[3]  
GEHAN EA, 1984, CANCER-AM CANCER SOC, V54, P1204, DOI 10.1002/1097-0142(19840915)54:1+<1204::AID-CNCR2820541318>3.0.CO
[4]  
2-Z
[5]   QUALITY ASSURANCE CONTROL IN THE EORTC COOPERATIVE GROUP OF RADIOTHERAPY .1. ASSESSMENT OF RADIOTHERAPY STAFF AND EQUIPMENT [J].
HORIOT, JC ;
JOHANSSON, KA ;
GONZALEZ, DG ;
VANDERSCHUEREN, E ;
VANDENBOGAERT, W ;
NOTTER, G .
RADIOTHERAPY AND ONCOLOGY, 1986, 6 (04) :275-284
[6]   WORKSHOP OF THE EORTC RADIOTHERAPY GROUP ON QUALITY ASSURANCE IN COOPERATIVE TRIALS OF RADIOTHERAPY - A RECOMMENDATION FOR EORTC COOPERATIVE GROUPS [J].
JOHANSSON, KA ;
HANSON, WF ;
HORIOT, JC .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (03) :201-203
[7]   QUALITY ASSURANCE CONTROL IN THE EORTC COOPERATIVE GROUP OF RADIOTHERAPY .3. INTERCOMPARISON IN AN ANATOMICAL PHANTOM [J].
JOHANSSON, KA ;
HORIOT, JC ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1987, 9 (04) :289-298
[8]   QUALITY ASSURANCE CONTROL IN THE EORTC COOPERATIVE GROUP OF RADIOTHERAPY .2. DOSIMETRIC INTERCOMPARISON [J].
JOHANSSON, KA ;
HORIOT, JC ;
VANDAM, J ;
LEPINOY, D ;
SENTENAC, I ;
SERNBO, G .
RADIOTHERAPY AND ONCOLOGY, 1986, 7 (03) :269-279
[9]   METHODS OF QUALITY-CONTROL AND OF CONTINUOUS AUDIT PROCEDURES FOR CONTROLLED CLINICAL-TRIALS [J].
KNATTERUD, GL .
CONTROLLED CLINICAL TRIALS, 1981, 1 (04) :327-332
[10]   QUALITY ASSURANCE PHYSICS DOSIMETRY [J].
SUNTHARALINGAM, N ;
JOHANSSON, KA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 :S21-S24