DETERMINATION OF ALENDRONATE IN PHARMACEUTICAL DOSAGE FORMULATIONS BY ION CHROMATOGRAPHY WITH CONDUCTIVITY DETECTION

被引:62
作者
TSAI, EW
IP, DP
BROOKS, MA
机构
[1] Merck Sharp and Dohme Research Laboratories, West Point
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 596卷 / 02期
关键词
D O I
10.1016/0021-9673(92)85010-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed and validated for the direct determination in pharmaceutical dosage formulations of alendronate, a non-chromophoric compound, It is based on the use of single-column ion chromatography with conductivity detection that obviates the need for the tedious chemical derivatization procedures that are required for UV and fluorescence detection. Diluted samples of 0.05 mg/ml were chromatographed directly on a Waters IC-Pak HR anion-exchange column or a Dionex OmniPac PAX-100 column with dilute nitric acid as the mobile phase followed by conductivity detection. The method was validated and shown to be precise, accurate and specific for the assay of alendronate in intravenous (i.v.) solution and tablet formulations. The ruggedness of the assay was studied by generating data from four different instruments. Also established was the equivalence between this method and a previously reported high-performance liquid chromatographic method with 9-fluorenylmethyl chloroformate derivatization and UV detection. Application of the method to the determination of alendronate in i.v. and tablet formulations is presented and the performances of the Waters IC-Pak HR and Dionex OmniPac columns are discussed.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 15 条
[1]   DETERMINATION OF (DICHLOROMETHYLENE)DIPHOSPHONATE IN PHYSIOLOGICAL FLUIDS BY ION-EXCHANGE CHROMATOGRAPHY WITH PHOSPHORUS-SELECTIVE DETECTION [J].
CHESTER, TL ;
LEWIS, EC ;
BENEDICT, JJ ;
SUNBERG, RJ ;
TETTENHORST, WC .
JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01) :17-25
[2]   ASSAY OF 1-HYDROXY-3-AMINOPROPYLIDENE-1,1-BISPHOSPHONATE AND RELATED BISPHOSPHONATES IN HUMAN-URINE AND PLASMA BY HIGH-PERFORMANCE ION CHROMATOGRAPHY [J].
DALEYYATES, PT ;
GIFFORD, LA ;
HOGGARTH, CR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (02) :329-338
[3]  
DEMARCO JD, 1989, J PHARM BIOMED ANAL, V12, P1719
[4]  
DENHARTIGH J, 1989, 3RD INT S DRUG AN AN, P114
[5]   DETERMINATION OF THE BISPHOSPHONATE PAMIDRONATE DISODIUM IN URINE BY PRE-COLUMN DERIVATIZATION WITH FLUORESCAMINE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION [J].
FLESCH, G ;
HAUFFE, SA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (02) :446-451
[6]  
FORBES KA, 1989, ADV ION CHROMATOGRAP, P487
[7]   CATION CHROMATOGRAPHY WITH A CONDUCTIVITY DETECTOR [J].
FRITZ, JS ;
GJERDE, DT ;
BECKER, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (09) :1519-1522
[8]   ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS [J].
GJERDE, DT ;
FRITZ, JS ;
SCHMUCKLER, G .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :509-519
[9]   ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS .2. [J].
GJERDE, DT ;
SCHMUCKLER, G ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY, 1980, 187 (01) :35-45
[10]  
GJERDE DT, 1987, ION CHROMATOGRAPHY, P133