RAPID SAMPLE PRECONCENTRATION BY SPRAY DEPOSITION FOR ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA SPECTROMETRY

被引:9
作者
ALARY, JF [1 ]
SALIN, ED [1 ]
机构
[1] MCGILL UNIV,DEPT CHEM,MONTREAL,PQ H3A 2K6,CANADA
关键词
D O I
10.1016/0584-8547(94)00133-G
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The deposition of aqueous sample in an electrothermal vaporization unit (ETV) is implemented by spraying onto a graphite tube heated at 160 degrees C. The water is evaporated continuously and vented by a flow of argon, leaving the analytes on the inner walls of the graphite cuvet. The analytes are later atomized at high temperature and directly to an inductively coupled plasma for atomic emission spectrometry (ICP-AES). The effects of observation height, argon flow in the furnace unit at atomization, and plasma energy on the signal-to-noise ratio were studied. The combination of the advantages of ETV with a sample volume of 1 ml provides detection limits for Cd (0.06 ng/ml), Pb (0.3 ng/ml), Zn (0.02 ng/ml) and Cu (0.04 ng/ml) which are an improvement of two orders of magnitude when compared with conventional nebulization. Moreover, the ETV allows a more convenient interface to the plasma than similar direct sample insertion (DSI) experiments.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 20 条
[1]   ANALYSIS OF URINE USING INDUCTIVELY-COUPLED PLASMA EMISSION-SPECTROSCOPY WITH GRAPHITE ROD ELECTROTHERMAL VAPORIZATION [J].
BARNES, RM ;
FODOR, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (09) :1191-1202
[2]   EVALUATION OF A MODIFIED COMMERCIAL GRAPHITE-FURNACE FOR REDUCTION OF ISOBARIC INTERFERENCES IN ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
CAREY, JM ;
EVANS, EH ;
CARUSO, JA ;
SHEN, WL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1711-1721
[3]   OPTICAL EMISSION SPECTROMETRY WITH AN INDUCTIVELY COUPLED RADIOFREQUENCY ARGON PLASMA SOURCE AND SAMPLE INTRODUCTION WITH A GRAPHITE ROD ELECTROTHERMAL VAPORIZATION DEVICE .1. INSTRUMENTAL ASSEMBLY AND PERFORMANCE-CHARACTERISTICS [J].
GUNN, AM ;
MILLARD, DL ;
KIRKBRIGHT, GF .
ANALYST, 1978, 103 (1231) :1066-1073
[4]  
HIEFTJE GM, 1972, ANAL CHEM, V44, pA69, DOI 10.1021/ac60315a752
[5]   TRACE-ELEMENT ANALYSIS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH ELECTROTHERMAL VAPORIZATION METHOD [J].
IDA, I ;
YOSHIKAWA, H ;
ISHIBASHI, Y ;
GUNJI, N .
ANALYTICAL SCIENCES, 1989, 5 (05) :615-618
[6]  
KANH HL, 1978, IND RES, V20, P101
[7]   INTERPRETING SOME ANALYTICAL CHARACTERISTICS OF THERMAL DISPERSION METHODS USED FOR SAMPLE INTRODUCTION IN ATOMIC SPECTROMETRY [J].
KANTOR, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (9-11) :1299-1320
[8]  
KARANASSIOS V, 1989, SPECTROCHIM ACTA REV, V12, P1387
[9]  
LEGERE G, 1982, ICP INFORM NEWSL, V13, P521
[10]  
MATOUSEK JP, 1973, TALANTA, V24, P315