SIMULTANEOUS QUANTITATION OF AMPHETAMINE AND 4'-HYDROXYAMPHETAMINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:12
作者
LAW, MYL [1 ]
MOODY, DE [1 ]
机构
[1] UNIV UTAH,DEPT PHARMACOL & TOXICOL,CTR HUMAN TOXICOL,SALT LAKE CITY,UT 84112
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 10期
关键词
D O I
10.1080/10826079508013958
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A relatively simple HPLC procedure used to detect and quantify amphetamine and 4'-hydroxyamphetamine in rat urine has been developed. Following Bond Elut(R) solid phase extraction, the two analytes - amphetamine and 4'-hydroxyamphetamine, and the two internal standards - methamphetamine and 4'-hydroxymethamphetamine were separated by HPLC using a phenyl column and detected by UV at 215 nm. The limit of quantitation for amphetamine and 4'-hydroxyamphetamine was 0.92 and 0.81 mu g/ml, respectively. Based on replicated analysis of controls at 1.6, 6.5, and 16.0 mu g/ml, the method is accurate (94 - 103% of target), and precise (% CVs of 1.3 - 5.2). The linear range of the assay is suitable for the quantitation of both analytes at urine concentrations that commonly result from administration of a single dose of amphetamine to the rat.
引用
收藏
页码:2029 / 2043
页数:15
相关论文
共 17 条
[1]  
AXELROD J, 1954, J PHARMACOL EXP THER, V110, P315
[2]   AMPHETAMINE AND METHAMPHETAMINE DETERMINATIONS IN BIOLOGICAL SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A REVIEW [J].
CAMPINSFALCO, P ;
SEVILLANOCABEZA, A ;
MOLINSLEGUA, C .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (04) :731-747
[3]   METABOLIC FATE OF AMPHETAMINE IN MAN AND OTHER SPECIES [J].
DRING, LG ;
SMITH, RL ;
WILLIAMS, RT .
BIOCHEMICAL JOURNAL, 1970, 116 (03) :425-&
[4]   AN INVESTIGATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE ANALYSIS OF AMPHETAMINES [J].
FARRELL, BM ;
JEFFERIES, TM .
JOURNAL OF CHROMATOGRAPHY, 1983, 272 (01) :111-128
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF BASIC DRUGS ON SILICA COLUMNS USING NON-AQUEOUS IONIC ELUENTS .1. FACTORS INFLUENCING RETENTION, PEAK SHAPE AND DETECTOR RESPONSE [J].
FLANAGAN, RJ ;
JANE, I .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (02) :173-189
[6]  
GREEN CE, 1986, J PHARMACOL EXP THER, V237, P931
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF BASIC DRUGS ON SILICA COLUMNS USING NON-AQUEOUS IONIC ELUENTS .2. APPLICATION OF UV, FLUORESCENCE AND ELECTROCHEMICAL OXIDATION DETECTION [J].
JANE, I ;
MCKINNON, A ;
FLANAGAN, RJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (02) :191-225
[8]   USE OF BONDED-PHASE SILICA SORBENTS FOR RAPID SAMPLING OF IMPURITIES IN ILLICIT AMPHETAMINE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSES [J].
LAMBRECHTS, M ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY, 1985, 331 (02) :339-348
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY RETENTION DATA FOR 84 BASIC DRUGS OF FORENSIC INTEREST ON A SILICA COLUMN USING AN AQUEOUS METHANOL ELUENT [J].
LAW, B ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (01) :165-172
[10]   THE IMPORTANCE OF IONIZATION IN THE ACTIVITY OF SYMPATHOMIMETIC AMINES [J].
LEWIS, GP .
BRITISH JOURNAL OF PHARMACOLOGY AND CHEMOTHERAPY, 1954, 9 (04) :488-493