EFFECT OF THE AMOUNT OF INTERNAL STANDARD ON THE PRECISION OF AN ANALYTICAL METHOD

被引:2
作者
JEMAL, M [1 ]
BERGUM, J [1 ]
机构
[1] BRISTOL MYERS SQUIBB CO,NONCLIN BIOSTAT,NEW BRUNSWICK,NJ 08903
关键词
D O I
10.1002/j.1552-4604.1992.tb05781.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In an earlier published paper,2 a confidence interval approach was used to show that the use of a large amount of internal standard (relative to the analyte) would adversely affect the precision of the analytical method. However, the confidence intervals were not calculated correctly. The authors recalculated the confidence intervals and found that there is no effect on the precision as measured by the confidence intervals.
引用
收藏
页码:676 / 677
页数:2
相关论文
共 3 条
[1]   APPLICATIONS TO ANALYTIC CHEMISTRY - AN EVALUATION OF STABLE ISOTOPES IN MASS-SPECTRAL DRUG ASSAYS [J].
GARLAND, WA ;
BARBALAS, MP .
JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 26 (06) :412-418
[2]  
GARLAND WA, 1990, DEC C AN METH VAL AR
[3]  
SNEDECOR GW, 1967, STATISTICAL METHODS, P159