ANALYSIS OF CARBAMATE PESTICIDES BY PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY

被引:14
作者
BERGER, TA
WILSON, WH
DEYE, JF
机构
[1] Hewlett-Packard, Wilmington, DE
关键词
D O I
10.1093/chromsci/32.5.179
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The carbamate pesticides in EPA Method 531.1 are separated in 9 min by packed-column supercritical fluid chromatography under steady-state conditions. All (except the naphthol degradation product of carbaryl) are directly, selectively detected without derivatization using a nitrogen-phosphorus detector (NPD). All the compounds are simultaneously detected by UV absorption, offering additional qualitative information. Solid-phase extraction is used to preconcentrate the solutes and change the solvent from water to ethyl acetate. Preliminary detection limits as low as 110 parts per trillion are found. Similar results are obtained when the loop of the injection valve is replaced with a short precolumn. Water samples are pumped through the precolumn, which is then dried and re-wetted with 5 µL methanol. Chromatographic selectivity is a complex function of temperature, pressure, and composition with many peak reversals. The carbamates and two groups of breakdown products each exhibit different selectivities. © 1994 Oxford University Press.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 18 条
  • [1] ASHRAF S, 1991, HRC-J HIGH RES CHROM, V14, P29, DOI 10.1002/jhrc.1240140108
  • [2] SOLVENT-VENTED INJECTION IN THE ANALYSIS OF AGROCHEMICALS BY CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    ASHRAF, S
    BARTLE, KD
    CLIFFORD, AA
    DAVIES, IL
    MOULDER, R
    [J]. CHROMATOGRAPHIA, 1990, 30 (11-12) : 618 - 620
  • [3] BERGER TA, 1991, HRC-J HIGH RES CHROM, V14, P312
  • [4] CAPILLARY AND PACKED-COLUMN SFC/MS
    BERRY, AJ
    GAMES, DE
    MYLCHREEST, IC
    PERKINS, JR
    PLEASANCE, S
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (01): : 61 - 64
  • [5] CHANG HCK, 1990, J CHROMATOGR SCI, V28, P29
  • [6] CHARACTERIZATION OF THE NITROGEN AND PHOSPHORUS THERMIONIC DETECTOR RESPONSE IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    DAVID, PA
    NOVOTNY, M
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (18) : 2082 - 2086
  • [7] PRESSURE PROGRAMMED MICROBORE COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY FOR THE DETERMINATION OF ORGANO-PHOSPHORUS INSECTICIDES
    KALINOSKI, HT
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (06) : 529 - 535
  • [8] KENNEDY S, 1988, LC GC-MAG SEP SCI, V6, P930
  • [9] CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY WITH DUAL-FLAME PHOTOMETRIC DETECTION
    MARKIDES, KE
    LEE, ED
    BOLICK, R
    LEE, ML
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (04) : 740 - 743
  • [10] MCNALLY ME, 1988, LC GC-MAG SEP SCI, V6, P816