IMPROVED DETECTION LIMIT FOR CATECHOLAMINES USING LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY WITH A CARBON INTERDIGITATED ARRAY MICROELECTRODE

被引:50
作者
NIWA, O [1 ]
TABEI, H [1 ]
SOLOMON, BP [1 ]
XIE, FM [1 ]
KISSINGER, PT [1 ]
机构
[1] BIOANALYT SYST INC, W LAFAYETTE, IN 47906 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1995年 / 670卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00145-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection limit of catecholamines can be lowered by using a carbon-based interdigitated array (IDA) microelectrode as a detector for liquid chromatography (LC). The IDA electrode is more sensitive than conventional glassy carbon electrodes due to the high current density caused by radial diffusion at each microband, and redox cycling between two microband arrays. Since the number of redox cycles increases at lower flow-rates, the carbon IDA is particularly useful for microbore LC. In an LC system with a l-mm microbore column and a carbon IDA electrode, the peak height of dopamine (DA) and DOPAC did not decrease with decreasing flow-rate because of this redox cycling. A low detection limit of 5 fg (32 amol) and 9.6 fg (57 amol) was obtained for DA and DOPAC due to the high current density and low background noise level (0.1 pA) at the carbon IDA electrode. The total charge generated by oxidizing DA at the anodic array was more than the value calculated by assuming that all the DA molecules were oxidized.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 21 条
[1]   ELECTROCHEMICAL RESPONSE AT MICROARRAY ELECTRODES IN FLOWING STREAMS AND DETERMINATION OF CATECHOLAMINES [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2206-2210
[2]   QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS [J].
AOKI, K ;
MORITA, M ;
NIWA, O ;
TABEI, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :269-282
[3]   SIMULTANEOUS MEASUREMENT OF SEROTONIN, CATECHOLAMINES AND THEIR METABOLITES IN MOUSE-BRAIN HOMOGENATES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A MICROBORE COLUMN AND DUAL ELECTROCHEMICAL DETECTION [J].
CHENG, FC ;
KUO, JS ;
SHIH, Y ;
LAI, JS ;
NI, DR ;
CHIA, LG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 615 (02) :225-236
[4]   DETERMINATION OF CATECHOLAMINES IN TISSUE AND BODY-FLUIDS USING MICROBORE HPLC WITH AMPEROMETRIC DETECTION [J].
DURKIN, TA ;
CALIGURI, EJ ;
MEFFORD, IN ;
LAKE, DM ;
MACDONALD, IA ;
SUNDSTROM, E ;
JONSSON, G .
LIFE SCIENCES, 1985, 37 (19) :1803-1810
[5]  
Fleischmann M, 1987, ULTRAMICROELECTRODES
[6]   MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM WITH MICRO PRECOLUMN AND DUAL ELECTROCHEMICAL DETECTOR FOR DIRECT INJECTION-ANALYSIS OF CATECHOLAMINES IN BODY-FLUIDS [J].
GOTO, M ;
NAKAMURA, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :33-42
[7]   NOVEL COULOMETRIC DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HAGIHARA, B ;
KOGOH, K ;
SAITO, M ;
SHIRAISHI, S ;
HASHIMOTO, T ;
TAGAWA, K ;
WADA, H .
JOURNAL OF CHROMATOGRAPHY, 1983, 281 (DEC) :59-71
[8]  
HUANG T, 1990, CURRENT SEP, V9, P139
[9]  
KENDRICK KM, 1990, CURR SEP, V9, P136
[10]  
KISSINGER PT, 1995, LABORATORY TECHNIQUE