EFFECTS OF INTRAATRIAL INJECTION OF COLORED MICROSPHERES ON SYSTEMIC HEMODYNAMICS AND REGIONAL BLOOD-FLOW IN RATS

被引:40
作者
KOBAYASHI, N
KOBAYASHI, K
KOUNO, K
HORINAKA, S
YAGI, S
机构
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1994年 / 266卷 / 05期
关键词
NONRADIOACTIVE MICROSPHERE; MICROSPHERE SUSPENDING SOLUTION;
D O I
10.1152/ajpheart.1994.266.5.H1910
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The hemodynamic effects of various numbers of colored nonradioactive microspheres (CMS) and those of accumulation of CMS caused by multiple sequential injection were evaluated in 51 Sprague-Dawley male rats. CMS (15 mu m) were injected into the left atrium. Regional blood flow and cardiac output were evaluated using the reference blood sample technique. Ficoll-70 was given after each blood sample withdrawal as a fluid replacement. A bolus injection of less than or equal to 1,000,000 CMS caused no significant hemodynamic disturbances. Amounts of 500,000 CMS can be repeatedly injected up to four times (cumulative dose of 2,000,000 CMS) without producing any adverse hemodynamic effects. The values of cardiac output obtained with the CMS technique were correlated well (r = 0.971, P < 0.0001) with those obtained with electromagnetic flow probes. An excellent reproducibility of organ blood flow was observed after four sequential injections of 500,000 CMS. This study establishes the limits of CMS that can be injected into the rat without inducing hemodynamic changes and also suggests that the CMS technique can be employed to evaluate cardiac output and regional blood flow precisely and repeatedly.
引用
收藏
页码:H1910 / H1917
页数:8
相关论文
共 21 条
[1]   BLOOD-VOLUME AND EXTRACELLULAR-SPACE (ECS) OF WHOLE-BODY AND SOME ORGANS OF RAT [J].
BIEWALD, N ;
BILLMEIER, J .
EXPERIENTIA, 1978, 34 (03) :412-413
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[4]   DEXTRAN AS A RADIOACTIVE MICROSPHERE SUSPENDING AGENT - SEVERE HYPOTENSIVE EFFECT IN RAT [J].
FLAIM, SF ;
MORRIS, ZQ ;
KENNEDY, TJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 235 (05) :H587-H591
[5]   EVALUATION OF NONRADIOACTIVE, COLORED MICROSPHERES FOR MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS [J].
HALE, SL ;
ALKER, KJ ;
KLONER, RA .
CIRCULATION, 1988, 78 (02) :428-434
[6]   REFERENCE SAMPLE MICROSPHERE METHOD - CARDIAC-OUTPUT AND BLOOD FLOWS IN CONSCIOUS RAT [J].
ISHISE, S ;
PEGRAM, BL ;
YAMAMOTO, J ;
KITAMURA, Y ;
FROHLICH, ED .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 239 (04) :H443-H449
[7]   THE CHRONIC EFFECT OF NITRENDIPINE ON HEART AND REGIONAL BLOOD-FLOW IN RENOVASCULAR HYPERTENSIVE RATS [J].
KOBAYASHI, K ;
TARAZI, RC .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (09) :1027-1034
[8]   CORONARY BLOOD-FLOW IN GENETIC CARDIAC-HYPERTROPHY [J].
KOBAYASHI, K ;
TARAZI, RC ;
LOVENBERG, W ;
RAKUSAN, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (09) :1360-1364
[9]  
KOBAYASHI K, 1983, HYPERTENSION, V5, P45
[10]   ROLE OF SITE OF MICROSPHERE INJECTION AND CATHETER POSITION ON SYSTEMIC AND REGIONAL HEMODYNAMICS IN RAT [J].
KOBRIN, I ;
KARDON, MB ;
OIGMAN, W ;
PEGRAM, BL ;
FROHLICH, ED .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (01) :H35-H39