EFFECT OF DETECTOR WEIGHTING FUNCTIONS ON THE POINT SPREAD FUNCTION OF HIGH-RESOLUTION PET TOMOGRAPHS - A SIMULATION STUDY

被引:24
作者
KARUTA, B [1 ]
LECOMTE, R [1 ]
机构
[1] UNIV SHERBROOKE,FAC MED,DEPT NUCL MED & RADIOBIOL,SHERBROOKE J1H 5N4,QUEBEC,CANADA
基金
英国医学研究理事会;
关键词
D O I
10.1109/42.158942
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Characterizing the point spread function (PSF) of a PET tomograph is important for assessing its performance and provides a useful model for restoration of the tomographic image. The PSF of ring PET tomograph is known to be spatially variant and difficult to obtain because it must be reconstructed from projections. A mathematical model was developed to simulate the data acquisition from a point source and to reconstruct the PSF taking into account weighting functions to describe the detector response functions. In order to investigate the effect of the detector weighting function on the PSF, the reconstruction, based on the filtered backprojection algorithm, was implemented with three classes of weighting functions of decreasing complexity: exact, locally invariant, and constant. Significant differences are observed to result from the three hypotheses and this is shown to lead to distorted PSF and to erroneous estimates of the intrinsic resolution off the center of the tomograph.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 18 条
[1]  
FLOYD CE, 1986, J NUCL MED, V27, P1577
[2]   COMPENSATION OF SPATIAL SYSTEM RESPONSE IN SPECT WITH CONJUGATE-GRADIENT RECONSTRUCTION TECHNIQUE [J].
FORMICONI, AR ;
PUPI, A ;
PASSERI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (01) :69-84
[3]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[4]   COMPENSATION FOR CRYSTAL PENETRATION IN HIGH-RESOLUTION POSITRON TOMOGRAPHY [J].
HUESMAN, RH ;
SALMERON, EM ;
BAKER, JR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1100-1107
[5]  
HUESMAN RH, 1983, NUCL MED BIOL, V1, P542
[6]  
Hunt B. R., 1977, DIGITAL IMAGE RESTOR
[7]   CONSTRAINED LEAST-SQUARES PROJECTION FILTERING - A NEW TECHNIQUE FOR THE RECONSTRUCTION OF EMISSION COMPUTED TOMOGRAPHIC-IMAGES [J].
HUTCHINS, GD ;
ROGERS, WL ;
CLINTHORNE, NH ;
KOEPPE, RA ;
HICHWA, RD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :379-383
[8]   CONSTRAINED LEAST-SQUARES FILTERING IN HIGH-RESOLUTION PET AND SPECT IMAGING [J].
HUTCHINS, GD ;
ROGERS, WL ;
CHIAO, P ;
RAYLMAN, RR ;
MURPHY, BW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :647-651
[9]   GEOMETRY STUDY OF A HIGH-RESOLUTION PET DETECTION SYSTEM USING SMALL DETECTORS [J].
LECOMTE, R ;
SCHMITT, D ;
LAMOUREUX, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :556-561
[10]   A BISMUTH GERMANATE-AVALANCHE PHOTODIODE MODULE DESIGNED FOR USE IN HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY [J].
LIGHTSTONE, AW ;
MCINTYRE, RJ ;
LECOMTE, R ;
SCHMITT, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :456-459