POSITION AND TIMING RESOLUTION OF INTERPOLATING CATHODE STRIP CHAMBERS IN A TEST BEAM

被引:7
作者
BENCZE, G
CHIKANIAN, A
DELLANEGRA, M
GRATCHEV, V
HERVE, A
KISELEV, O
MCCORKLE, S
MOHAMMADI, M
OCONNOR, P
POLYCHRONAKOS, V
PROKOFIEV, O
RADEKA, V
RADERMACHER, E
SEEZ, C
SHANK, J
SMITH, G
SONDERICKER, J
STEPHANI, D
SZONCSO, F
TCHERNIATINE, V
VANYASHIN, A
WALZEL, G
WHITAKER, S
WROCHNA, G
WULZ, CE
YU, B
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
[2] CERN,CH-1211 GENEVA,SWITZERLAND
[3] YALE UNIV,DEPT PHYS,NEW HAVEN,CT 06511
[4] ST PETERSBURG NUCL PHYS INST,GATCHINA 188530,RUSSIA
[5] SUNY STONY BROOK,DEPT PHYS,STONY BROOK,NY 11794
[6] BOSTON UNIV,DEPT PHYS,BOSTON,MA 02215
[7] OSTERREICH AKAKD WISSENSCH,HEPHY,VIENNA,AUSTRIA
关键词
D O I
10.1016/0168-9002(94)01525-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Design and construction details are presented of a four-layer, position sensitive, cathode strip chamber and a low cost, highly multiplexed readout system based on monolithic circuit technology that are well suited for a muon detector at future hadron colliders. Track location is determined by interpolation of the cathode induced charge, using a new design with intermediate strips between readout nodes to reduce the number of channels and improve position resolution and linearity, Results are reported from tests with an Fe-55 source and a 300 GeV/c muon beam in RD5 at CERN. The beam test demonstrated position resolution of 40 mu m per layer which is less than 1% of the readout pitch, The timing resolution for the entire four-layer detector was 3.6 ns r.m.s. which is adequate for fully efficient beam crossing identification in an LHC experiment.
引用
收藏
页码:40 / 54
页数:15
相关论文
共 29 条
[1]  
ALKHAZOW GD, 1900, NUCL INSTRUM METHODS, V89, P155
[2]   AMPLEX, A LOW-NOISE, LOW-POWER ANALOG CMOS SIGNAL PROCESSOR FOR MULTI-ELEMENT SILICON PARTICLE DETECTORS [J].
BEUVILLE, E ;
BORER, K ;
CHESI, E ;
HEIJNE, EHM ;
JARRON, P ;
LISOWSKI, B ;
SINGH, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :157-167
[3]   HIGH-ACCURACY, BIDIMENSIONAL READOUT OF PROPORTIONAL CHAMBERS WITH SHORT RESOLUTION TIMES [J].
BRESKIN, A ;
CHARPAK, G ;
DEMIERRE, C ;
MAJEWSKI, S ;
POLICARPO, A ;
SAULI, F ;
SANTIARD, JC .
NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (01) :29-39
[4]   SOME DEVELOPMENTS IN OPERATION OF MULTIWIRE PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
RAHM, D ;
STEINER, H .
NUCLEAR INSTRUMENTS & METHODS, 1970, 80 (01) :13-+
[5]   PROGRESS IN HIGH-ACCURACY PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
PETERSEN, G ;
POLICARPO, A ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (03) :471-482
[6]   HIGH-ACCURACY, 2-DIMENSIONAL READOUT IN MULTIWIRE PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS, 1973, 113 (03) :381-385
[7]   FAST RICH DETECTOR USING A MWPC AT ATMOSPHERIC-PRESSURE WITH A PAD STRUCTURE READOUT BY VLSI CIRCUITS [J].
CHESI, E ;
MARTINENGO, P ;
PIUZ, F ;
WILLIAMS, TD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (03) :602-607
[8]   STUDY OF POSITION RESOLUTION FOR CATHODE READOUT MWPC WITH MEASUREMENT OF INDUCED CHARGE-DISTRIBUTION [J].
CHIBA, J ;
IWASAKI, H ;
KAGEYAMA, T ;
KURIBAYASHI, S ;
NAKAMURA, K ;
SUMIYOSHI, T ;
TAKEDA, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :451-463
[9]   FAST GAS-MIXTURES FOR GAS-FILLED PARTICLE DETECTORS [J].
CHRISTOPHOROU, LG ;
MCCORKLE, DL ;
MAXEY, DV ;
CARTER, JG .
NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01) :141-149
[10]   GAS-MIXTURES FOR TRANSITION RADIATION DETECTORS AT HIGH-LUMINOSITY COLLIDERS [J].
DOLGOSHEIN, B ;
POTEKHIN, M ;
ROMANYUK, A ;
SOSNOVTSEV, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03) :473-477