THE INFLUENCE OF LACTOSE PARTICLE-SIZE ON SPHERONIZATION OF EXTRUDATE PROCESSED BY A RAM EXTRUDER

被引:38
作者
FIELDEN, KE
NEWTON, JM
ROWE, RC
机构
[1] UNIV LONDON,SCH PHARM,29-39 BRUNSWICK SQ,LONDON WC1N 1AX,ENGLAND
[2] WELLCOME FDN LTD,DARTFORD DA1 5AH,KENT,ENGLAND
[3] ICI PLC,PHARMACEUT,MACCLESFIELD SK10 4TG,CHESHIRE,ENGLAND
关键词
EXTRUSION SPHERONIZATION; MICROCRYSTALLINE CELLULOSE; LACTOSE PARTICLE SIZE EFFECT; RAM EXTRUDER (INCLUDING DIE DIAMETER); SPHERICAL GRANULE;
D O I
10.1016/0378-5173(92)90013-R
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The spheronization of extrudate produced by a ram extruder fitted with either 1.0 or 1.5 mm diameter dies from mixtures of microcrystalline cellulose, lactose (with median diameter of either 18.0 or 117.0-mu-m) and water has been observed. The spherical granules produced have been characterized in terms of their median length (number diameter by microscope) and width (weight diameter by sieving) and the roundness ('One Plane Critical Stability'), width and length (microscope observation) of the most frequently occurring size fraction. Extrudate produced through both 1.0 and 1.5 mm diameter dies with the fine particle size lactose formed granules within 5 min which were well rounded and of a narrow size distribution. Extrudate produced through both the 1.0 and 1.5 mm diameter dies with the coarse grade of lactose, produced spheres, but these were considerably larger in size and had a larger range of size, due to agglomeration of the granules. The changes in shape and size could be observed within the spheronizer by using a photographic technique. The median diameter of spheroids produced by the controlled spheronization of the fine grade lactose mixture was about 1.2 times the diameter of the die producing the extrudate. The median diameter of the spheroids produced by the uncontrolled spheronization of the coarse grade lactose mixture was not related to the die diameter. In fact, extrudate produced from the 1.0 and 1.5 mm dies both produced spheroids of approx. 3.0 mm diameter. The reasons for the difference in processing of the two particle size fractions of lactose appear to be associated with the movement of water in the formulation.
引用
收藏
页码:205 / 224
页数:20
相关论文
共 20 条
[1]  
ANDERSEN AH, 1990, RHEOLOGY OF FOOD, PHARMACEUTICAL AND BIOLOGICAL MATERIALS WITH GENERAL RHEOLOGY, P258
[2]  
BAINE SD, 1991, INT J PHARM, V69, P233
[3]  
BATAILLE B, 1990, PHARM ACTA HELV, V65, P334
[4]  
BODMEIER R, 1986, 4TH C INT TECH PHARM, V1, P293
[5]  
CAPES CE, 1965, TRANS INST CHEM ENG, V43, pT116
[6]   CHARACTERIZATION OF THE SPHERICITY OF PARTICLES BY THE ONE PLANE CRITICAL STABILITY [J].
CHAPMAN, SR ;
ROWE, RC ;
NEWTON, JM .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1988, 40 (07) :503-505
[7]  
CHAPMAN SR, 1986, 4TH P C INT TECH PHA, V3, P9
[8]  
CONINE JW, 1970, DRUG COSMET IND, V106, P38
[9]   THE EFFECT OF LACTOSE PARTICLE-SIZE ON THE EXTRUSION PROPERTIES OF MICROCRYSTALLINE CELLULOSE-LACTOSE MIXTURES [J].
FIELDEN, KE ;
NEWTON, JM ;
ROWE, RC .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1989, 41 (04) :217-221
[10]   MOVEMENT OF LIQUIDS THROUGH POWDER BEDS [J].
FIELDEN, KE ;
NEWTON, JM ;
ROWE, RC .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1992, 79 (01) :47-60