PERFORMANCE OF DIRECT-CONTACT LATENT-HEAT STORAGE UNITS WITH 2 HYDRATED SALTS

被引:36
作者
FARID, MM [1 ]
KHALAF, AN [1 ]
机构
[1] UNIV BASRAH,DEPT CHEM ENGN,BASRAH,IRAQ
关键词
D O I
10.1016/0038-092X(94)90067-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of a direct contact latent heat storage unit, that consists of two columns with different hydrated salts, has been investigated. Na2CO3.10H2O (sodium carbonate decahydrate) and Na2S2O3.5H2O (sodium thiosulphate pentahydrate) were contained in separate columns both having an inside diameter and total length of 0.184 m and 1.0 m, respectively. During heat charge. the hot kerosene as a heat transfer fluid was bubbled through the sodium thiosulfate solution first. The partially cooled kerosene was then pumped to the second column containing the sodium carbonate solution, discharging most of its heat content. Flow direction was reversed during heat discharge. The continuous phase temperature in the two columns, as well as kerosene inlet and outlet temperatures, were measured continuously. Results showed significant improvement in heat transfer rates by using two separate columns containing similar or different salts. The use of a combination of two different salts, having different crystallization temperatures, and contained in different columns connected in series, may provide better means of heat storage by allowing the system to operate as a phase change storage for longer periods of operation. This is particularly suitable for solar energy applications in which the collector temperature may vary significantly during the day.
引用
收藏
页码:179 / 189
页数:11
相关论文
共 17 条
[1]   THERMAL-ENERGY STORAGE IN SUPERSATURATED SALT-SOLUTIONS [J].
BARRETT, PF ;
BEST, BR ;
OLDHAM, KB .
MATERIALS CHEMISTRY AND PHYSICS, 1984, 10 (01) :39-49
[2]   THERMAL-ENERGY STORAGE USING SODIUM-SULFATE DECAHYDRATE AND WATER [J].
BISWAS, DR .
SOLAR ENERGY, 1977, 19 (01) :99-100
[3]  
COSTELLO VA, 1978, DEC ASME M SAN FRANC
[4]  
EDIE DD, 1976, SOLAR TECHNOLOGY 70S, V8, P227
[5]  
ETHERINGTON TL, 1957, HEATING PIPING A DEC, P147
[6]   PERFORMANCE OF DIRECT CONTACT LATENT-HEAT STORAGE UNIT [J].
FARID, M ;
YACOUB, K .
SOLAR ENERGY, 1989, 43 (04) :237-251
[7]  
Farid M. M., 1986, Journal of Solar Energy Research, V4, P11
[8]   THERMAL PERFORMANCE OF A HEAT-STORAGE MODULE USING PCMS WITH DIFFERENT MELTING TEMPERATURES - MATHEMATICAL-MODELING [J].
FARID, MM ;
KANZAWA, A .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (02) :152-157
[9]   THERMAL PERFORMANCE OF A HEAT-STORAGE MODULE USING PCMS WITH DIFFERENT MELTING TEMPERATURE - EXPERIMENTAL [J].
FARID, MM ;
KIM, Y ;
KANSAWA, A .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :125-131
[10]  
FARID MM, 1988, SEP C SEL PROBL CHEM