PERCUTANEOUS NEEDLE-BIOPSY OF LOCALIZED PULMONARY, MEDIASTINAL, AND PLEURAL DISEASED TISSUE WITH AN AUTOMATIC DISPOSABLE GUILLOTINE SOFT-TISSUE NEEDLE - PRELIMINARY-RESULTS

被引:24
作者
NOPPEN, MMP [1 ]
DEMEY, J [1 ]
MEYSMAN, M [1 ]
OPDEBEECK, B [1 ]
VINCKEN, WG [1 ]
OSTEAUX, M [1 ]
机构
[1] FREE UNIV BRUSSELS,ACAD HOSP,DEPT RADIOL,B-1090 BRUSSELS,BELGIUM
关键词
BIOPSY TECHNIQUE; LUNG NEOPLASMS; PLEURAL NEOPLASMS; THORACIC BIOPSY;
D O I
10.1378/chest.107.6.1615
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Percutaneous needle biopsy (PNB) of localized thoracic disease has become a widespread procedure in many institutions. The development of special small caliber needles has increased the diagnostic yield of PNB partly by increasing the amount of tissue from biopsy, often enabling histologic examination. Nevertheless, in a significant number of patients only cytopathologic examination is possible on the retrieved biopsy fragments, necessitating the presence of a trained cytopathologist in the biopsy room. Furthermore multiple biopsy needle passages often are required, increasing the risk for complications such as pneumothorax. We have evaluated the use of a small-caliber tissue biopsy cutting needle, consistently yielding sufficient biopsy tissue for histologic examination. In 25 pleural and mediastinal lesions, which could be biopsied without passage through aerated lung, there was a 93% sensitivity (7% false-negative results) for neoplasm and a 100% accuracy for benign disease. There were no complications. In 32 patients with lesions of 1 cm in diameter or more surrounded with aerated lung tissue, adequate histologic examination was feasible on every biopsy specimen after only one needle passage. There was an 87% sensitivity of PNB in neoplastic disease (13% false-negatives). In the patients with benign disease, there was a 100% accuracy. There was a 15.6% risk for pneumothorax. In only one patient (3%), however, was chest drainage necessary. One patient (3%) had mild hemoptysis. We conclude that percutaneous biopsy of localized pulmonary, pleural, and mediastinal lesions with a new small-caliber automatic guillotine cutting needle is safe and efficient, enabling recovery of sufficient tissue for histologic examination with a single-pass procedure, thus minimizing the risk for pneumothorax, eliminating the need for a cytopathologist in the biopsy room, and shortening the duration of the procedure.
引用
收藏
页码:1615 / 1620
页数:6
相关论文
共 13 条
[1]   SPECIALLY DESIGNED CUTTING ASPIRATION NEEDLE FOR LUNG-BIOPSY [J].
BALLARD, GL ;
BOYD, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 130 (05) :899-903
[2]   THIN NEEDLE ASPIRATION BIOPSY OF THORACIC LESIONS - IMPACT ON HOSPITAL CHARGES AND PATTERNS OF PATIENT-CARE [J].
GOBIEN, RP ;
BOUCHARD, EA ;
GOBIEN, BS ;
VALICENTI, JF ;
VUJIC, I .
RADIOLOGY, 1983, 148 (01) :65-67
[3]   CLINICAL COMPARISON OF SMALL-CALIBER AND LARGE-CALIBER CUTTING NEEDLES FOR BIOPSY [J].
HAAGA, JR ;
LIPUMA, JP ;
BRYAN, PJ ;
BALSARA, VJ ;
COHEN, AM .
RADIOLOGY, 1983, 146 (03) :665-667
[4]   DIAGNOSTIC ACCURACY AND COMPLICATIONS OF CLOSED LUNG BIOPSIES [J].
HERMAN, PG ;
HESSEL, SJ .
RADIOLOGY, 1977, 125 (01) :11-14
[5]  
JOHNSON RD, 1983, ANN CLIN LAB SCI, V13, P225
[6]   RAPID CYTOLOGY TO DECREASE PNEUMOTHORAX INCIDENCE AFTER PERCUTANEOUS BIOPSY [J].
JOHNSRUDE, IS ;
SILVERMAN, JF ;
WEAVER, MD ;
MCCONNELL, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) :793-794
[7]   INTERVENTIONAL RADIOLOGY IN THE CHEST AND ABDOMEN [J].
MUELLER, PR ;
VANSONNENBERG, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (19) :1364-1374
[8]  
STITIK FP, 1989, BIOPSY TECHNIQUES PU, P81
[9]   PERCUTANEOUS PULMONARY NEEDLE BIOPSY - AN IMPROVED NEEDLE FOR A SIMPLE DIRECT METHOD OF DIAGNOSIS [J].
TURNER, AF ;
SARGENT, EN .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1968, 104 (04) :846-&
[10]   PERCUTANEOUS BIOPSY OF DIFFICULT MEDIASTINAL, HILAR, AND PULMONARY-LESIONS BY COMPUTED-TOMOGRAPHIC GUIDANCE AND A MODIFIED CO-AXIAL TECHNIQUE [J].
VANSONNENBERG, E ;
LIN, AS ;
DEUTSCH, AL ;
MATTREY, RF .
RADIOLOGY, 1983, 148 (01) :300-302