EXPERIMENTAL EVALUATION AND CLINICAL USE IN THE HEAD AND NECK OF A 3M/PRECISE(R) MICROVASCULAR ANASTOMOTIC DEVICE

被引:6
作者
BORJAMORANT, A
NAVARROVILA, C
CUESTAGIL, M
MARTINSASTRE, R
机构
[1] General Hospital 'Gregorio Marañon', Maxillofacial Surgery Department, C/Dr. Esquerdo
来源
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY | 1995年 / 23卷 / 05期
关键词
D O I
10.1016/S1010-5182(05)80161-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Microvascular reconstructions in the head and neck are usually long operating time procedures. Mechanical anastomotic devices help to reduce operating time and can reduce anastomotic failures avoiding foreign bodies in the lumen of the vessel. One of these systems is the 3M/Precise(R) microvascular anastomotic device, it is a non-absorbable device, however, criticisms of this system have been directed to the fact that pulsation of the vessel wall against a rigid structure could lead to thinning of the vessel wall and aneurysm formation. No aneurysms have been found previously in other experimental models. Our experimental study on the aorta and vena cava of the rat comprises 25 arterial and 25 venous anastomoses. In the arteries, four proximal aneurysms were found, two of these were failures. In the venous anastomoses, no failures were found nor aneurysm formation. The system is very useful for performing clinical end to end venous anastomosis helping to reduce anastomotic failures. Aneurysms have been found in arteries although four different ring sizes were available. The device is less easy to use in them than in veins and sometimes can be difficult to apply, making manual suturing a better choice for clinical arterial anastomosis.
引用
收藏
页码:305 / 311
页数:7
相关论文
共 22 条
[1]  
BAHR W, 1994, 12 C EACMS HAG
[2]   MECHANICAL ANASTOMOSIS OF SMALL ARTERIES AND VEINS WITH THE UNILINK APPARATUS - A HISTOLOGIC AND SCANNING ELECTRON-MICROSCOPIC STUDY [J].
BERGGREN, A ;
OSTRUP, LT ;
LIDMAN, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1987, 80 (02) :274-283
[3]   CLINICAL-EXPERIENCE WITH THE UNILINK/3M PRECISE MICROVASCULAR ANASTOMOTIC DEVICE [J].
BERGGREN, A ;
OSTRUP, LT ;
RAGNARSSON, R .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1993, 27 (01) :35-39
[4]   A MICROVASCULAR ANASTOMOTIC DEVICE .1. A HEMODYNAMIC EVALUATION IN RABBIT FEMORAL ARTERIES AND VEINS [J].
BLAIR, WF ;
STEYERS, CM ;
BROWN, TD ;
GABLE, RH .
MICROSURGERY, 1989, 10 (01) :21-28
[5]   AN ABSORBABLE ANASTOMOTIC DEVICE FOR MICROVASCULAR SURGERY - EXPERIMENTAL STUDIES [J].
DANIEL, RK ;
OLDING, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 74 (03) :329-336
[6]   AN ABSORBABLE ANASTOMOTIC DEVICE FOR MICROVASCULAR SURGERY - CLINICAL-APPLICATIONS [J].
DANIEL, RK ;
OLDING, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 74 (03) :337-342
[7]  
DANIEL RK, 1990, J RECONSTR MICROSURG, V6, P351
[8]  
GILBERT RW, 1989, ARCH OTOLARYNGOL, V115, P970
[9]  
GILBERT RW, 1988, MICROSURG, V10, P40
[10]  
KIRSCH WM, 1992, J REPROD MED, V37, P581