THIN-FILM HIGH-TEMPERATURE SUPERCONDUCTING RF COILS FOR LOW-FIELD MRI

被引:51
作者
VANHETEREN, JG
JAMES, TW
BOURNE, LC
机构
[1] TOSHIBA AMERICA MRI INC,S SAN FRANCISCO,CA
[2] SUPERCONDUCTOR TECHNOL INC,SANTA BARBARA,CA 93111
关键词
RF COILS; SUPERCONDUCTORS;
D O I
10.1002/mrm.1910320315
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have built and tested a thin-film high temperature superconducting (HTS) surface coil for MRI at 0.064T. When placed as close as possible to a conductive sample, the 6.7-cm outer diameter HTS coil had a measured signal-to-noise ratio (SNR) 1.8 times higher than a room temperature copper coil of similar size and location. Our results predict that in some cases, SNR gains of about a factor of 2 can be attained in low-field MRI systems by substituting HTS surface coils for copper coils.
引用
收藏
页码:396 / 400
页数:5
相关论文
共 14 条
  • [1] A HIGH-TEMPERATURE SUPERCONDUCTING RECEIVER FOR NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY
    BLACK, RD
    EARLY, TA
    ROEMER, PB
    MUELLER, OM
    MOGROCAMPERO, A
    TURNER, LG
    JOHNSON, GA
    [J]. SCIENCE, 1993, 259 (5096) : 793 - 795
  • [2] TRANSPORT CHARACTERISTICS OF TL2BA2CACU2O8 BICRYSTAL GRAIN-BOUNDARY JUNCTIONS AT 77-K
    CARDONA, AH
    SUZUKI, H
    YAMASHITA, T
    YOUNG, KH
    BOURNE, LC
    [J]. APPLIED PHYSICS LETTERS, 1993, 62 (04) : 411 - 413
  • [3] AN INDUCTIVELY COUPLED, SERIES-TUNED NMR PROBE
    DECORPS, M
    BLONDET, P
    REUTENAUER, H
    ALBRAND, JP
    REMY, C
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (01) : 100 - 109
  • [4] THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
    EDELSTEIN, WA
    GLOVER, GH
    HARDY, CJ
    REDINGTON, RW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) : 604 - 618
  • [5] INVESTIGATION OF A WHOLE-BODY RECEIVER COIL OPERATING AT LIQUID-NITROGEN TEMPERATURES
    HALL, AS
    BARNARD, B
    MCARTHUR, P
    GILDERDALE, DJ
    YOUNG, IR
    BYDDER, GM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (02) : 230 - 235
  • [6] USE OF HIGH-TEMPERATURE SUPERCONDUCTOR IN A RECEIVER COIL FOR MAGNETIC-RESONANCE-IMAGING
    HALL, AS
    ALFORD, NM
    BUTTON, TW
    GILDERDALE, DJ
    GEHRING, KA
    YOUNG, IR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) : 340 - 343
  • [7] EPITAXIAL TL2CABA2CU2O8 THIN-FILMS WITH LOW 9.6-GHZ SURFACE-RESISTANCE AT HIGH-POWER AND ABOVE 77-K
    HAMMOND, RB
    NEGRETE, GV
    BOURNE, LC
    STROTHER, DD
    CARDONA, AH
    EDDY, MM
    [J]. APPLIED PHYSICS LETTERS, 1990, 57 (08) : 825 - 827
  • [8] SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES
    HOULT, DI
    LAUTERBUR, PC
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1979, 34 (02) : 425 - 433
  • [9] Jackson J D, 1975, CLASSICAL ELECTRODYN, P298
  • [10] KAUFMAN L, 1989, Magnetic Resonance Quarterly, V5, P283