POLYIMIDES AS BIOMATERIALS - PRELIMINARY BIOCOMPATIBILITY TESTING

被引:264
作者
RICHARDSON, RR [1 ]
MILLER, JA [1 ]
REICHERT, WM [1 ]
机构
[1] DUKE UNIV, DEPT BIOMED ENGN, DURHAM, NC 27706 USA
关键词
POLYIMIDES; CYTOTOXICITY; PROTEIN ADSORPTION; CLOTTING TIME; HEMOLYSIS;
D O I
10.1016/0142-9612(93)90183-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A number of commercially available polyimide materials were evaluated in vitro using a selected battery of levels I and II testing protocols prescribed by the National Institutes of Health Guidelines for Blood-Material Interactions. These procedures consisted of electron spectroscopy for chemical analysis and contact angle characterization surface studies, and protein adsorption, cell culture cytotoxicity, clotting time and haemolysis biocompatibility testing. The polyimide surfaces were invariant from the bulk composition with 60-80% C, 10-20% O and 2-5% N, producing advancing contact angles in the hydrophobic range (80-1000). Consequently, they adsorbed significant amounts of albumin (2-3 mug/cm2) and fibrinogen (0.5-0.8 mug/cm2). The polyimides also displayed an insignificant level of cytotoxicity and haemolysis, and clotting times ranged from 63 to 98% of normal. These clotting times and haemolytic index values were intermediate between the values observed for Teflon(R) and Silastic(R) controls. These factors, along with the strong adherence of polyimides to metal oxide substrates, indicate that polyimide materials are good candidates for further testing as encapsulants for implantable biosensors.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 29 条
  • [1] ANDRADE JD, 1986, ADV POLYM SCI, V79, P1
  • [2] Andrade JD, 1985, SURFACE INTERFACIAL, V2, P1
  • [3] THE INTERACTION OF PLASMA-PROTEINS WITH POLYMERS .1. RELATIONSHIP BETWEEN POLYMER SURFACE-ENERGY AND PROTEIN ADSORPTION-DESORPTION
    BASZKIN, A
    LYMAN, DJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (04): : 393 - 403
  • [4] Biggs R, 1984, HUMAN BLOOD COAGULAT
  • [5] BLACK J, 1981, BIOL PERFORMANCE MAT, P102
  • [6] CHANGES IN ADSORBED FIBRINOGEN AND ALBUMIN INTERACTIONS WITH POLYMERS INDICATED BY DECREASES IN DETERGENT ELUTABILITY
    BOHNERT, JL
    HORBETT, TA
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1986, 111 (02) : 363 - 378
  • [7] BORETOS JW, 1980, SYNTHETIC BIOMEDICAL, P187
  • [8] COOK CS, 1992, CLIN HEMATOLOGY PRIN, P605
  • [9] CHEMICAL SENSORS FOR INVIVO MONITORING - PACKAGING, BIOCOMPATIBILITY, STABILITY
    COUGHLAN, MP
    ALCOCK, SJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) : 87 - 91
  • [10] INFLUENCE OF ENDOGENOUS ALBUMIN BINDING ON BLOOD-MATERIAL INTERACTIONS
    EBERHART, RC
    MUNRO, MS
    FRAUTSCHI, JR
    LUBIN, M
    CLUBB, FJ
    MILLER, CW
    SEVASTIANOV, VI
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 516 : 78 - 95