Oxford meniscal bearing knee versus the Marmor knee in unicompartmental arthroplasty for arthrosis - A Swedish multicenter survival study

被引:115
作者
Lewold, S
Goodman, S
Knutson, K
Robertsson, O
Lidgren, L
机构
[1] Department of Orthopedics, Lund University Hospital, Lund
[2] Division of Orthopedic Surgery, Stanford University Medical Center, Stanford, CA
关键词
cumulative revision rate; unicompartmental prostheses; knee protheses;
D O I
10.1016/S0883-5403(05)80066-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In the Swedish Knee Arthroplasty Study, all 699 Oxford meniscal bearing cemented unicompartmental prostheses (Biomet, Bridgend, UK) were identified and analyzed regarding failure pattern and compared with all Marmor prostheses (Smith & Nephew Richards, Orthez, France) and with a time-, age-, and sex-marched subset of Marmor prostheses using survival statistics expressed as cumulative revision rates. After 1 year there was already a higher rate, and after 6 years the rate of the Oxford group was more than twice that of the Marmor group. There were 50 revisions in the Oxford group: dislocating, meniscus in 16, loosening of the femoral component in 6, tibial component in 4, both components in 4, contralateral arthrosis in 10, infection in 4, and technical failure with instability, pain, and/or impingement of the meniscal bearing anterior in the femoral condyle in 6. It is still unclear if the design with the sliding menisci will, in the long turn, reduce wear and loosening, thereby compensating for the initially inferior results. It is recommended that until this question is clarified, the Oxford knee should be used on a limited scale for long-term comparative studies only.
引用
收藏
页码:722 / 731
页数:10
相关论文
共 27 条
[1]  
Kozinn, Scott, Current concepts review: unicondylar knee arthroplasty, J Bone Joint Surg, 71 A, (1989)
[2]  
Lewold, Knutson, Lidgren, Reduced failure rate in knee prosthetic surgery with improved implantation technique, Clin Orthop Relat Res, 287, (1993)
[3]  
Ahlback, Osteoarthrosis of the knee: a radiographic investigation, Acta Radiol Diagn (Stockh), (1968)
[4]  
Lindstrand, Stenstrom, Lewold, Multicenter study of unicompartmental knee revision: PCA, Marmor, and St Georg compared in 3,777 cases of arthrosis, Acta Orthop Scand, 63, (1992)
[5]  
Lindstrand, Stenstrom, Polyethylene wear of the PCA unicompartmental knee: prospective 5 (4–8) year study of 120 arthrosis knees, Acta Orthop Scand, 63, (1992)
[6]  
Sherman, Goodfellow, Tibrewal, O'Connor, Bilateral Oxford meniscal knee arthroplasty, J R Soc Med, 78, (1985)
[7]  
Buechel, Pappas, New Jersey low contact stress knee replacement system: ten-year evaluation of meniscal bearings, Orthop Clin North Am, 20, (1989)
[8]  
Goodfellow, O'Connor, Clinical results of the Oxford knee: surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis, Clin Orthop, 205, (1986)
[9]  
Knutson, Lewold, Lidgren, Outcome of revision for failed unicompartmental knee arthroplasty for arthrosis, Presented as a poster exhibit at the Annual Meeting of the American Association of Orthopaedic Surgeons, (1992)
[10]  
Argenson, O'Connor, Polyethylene wear in meniscal knee replacement: a one to nine-year retrieval analysis of the Oxford knee, J Bone Joint Surg, 74 B, (1992)