CONSTRUCTION AND USES OF A CONCENTRIC CATHETER FOR GAS SAMPLING IN LUNG AIRWAYS

被引:5
作者
GAVRIELY, N
SOLWAY, J
ELAD, D
SHABTAIMUSIH, Y
GAVER, DP
GROTBERG, JB
DRAZEN, JM
机构
[1] TECHNION ISRAEL INST TECHNOL, RAPPAPORT FAMILY INST RES MED SCI, HAIFA, ISRAEL
[2] UNIV CHICAGO, PULM & CRIT CARE MED SECT, CHICAGO, IL 60637 USA
[3] NORTHWESTERN UNIV, MCCORMICK SCH ENGN & APPL SCI, DEPT BIOMED ENGN, EVANSTON, IL 60208 USA
[4] NORTHWESTERN UNIV, SCH MED, DEPT ANESTHESIA, CHICAGO, IL 60611 USA
[5] BRIGHAM & WOMENS HOSP, DEPT RESP, BOSTON, MA 02115 USA
[6] HARVARD UNIV, SCH PUBL HLTH, BOSTON, MA 02115 USA
[7] TULANE UNIV, DEPT BIOMED ENGN, NEW ORLEANS, LA 70118 USA
关键词
PULMONARY GAS TRANSPORT; ARTIFICIAL VENTILATION; ALTERNATIVE MODES OF VENTILATION; HIGH-FREQUENCY VENTILATION; CARDIOGENIC OSCILLATIONS;
D O I
10.1152/jappl.1993.74.6.3063
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A catheter for intra-airway sampling of gas concentrations was constructed from concentric polyethylene tubes. The internal tube (0.58 mm ID, 0.91 mm OD) was connected to a gas analyzer while the external tube (1.20 mm ID, 1.75 mm OD) was constantly flushed by air or a calibration gas, except during sampling. Injection and sampling dead spaces were 0.35 and 0.28 ml, respectively. Delay at 4-ml/min sampling rate was 4.0 +/- 0.2 s. The 0-90% step response to a sudden change in gas composition was 0.24 s when connected to a mass spectrometer. This catheter was used to assess tracer gas dispersion during oscillatory flow (1-20 Hz) in a straight long tube. Local concentrations measured through the catheter, after a small bolus of tracer gas was injected through the external tube, compared favorably with direct measurements through needles inserted via the tube wall and with theoretical predictions. The catheter was also used to measure intra-airway gas concentrations in dog airways during spontaneous breathing, conventional mechanical ventilation, high-frequency ventilation, high-frequency vibration ventilation, and constant-flow ventilation. It was placed by a fiber-optic bronchoscope and used to measure local quasi-steady concentrations of CO2 and local dispersion with the bolus method. The occurrence of catheter clogging with secretions was substantially reduced with flow through the external tube. Transmitting a calibration gas through the external tube facilitated in situ recalibration of the gas analyzer without removing the catheter. The use of this catheter improved the efficiency and accuracy of measurements of gas concentrations inside lung airways.
引用
收藏
页码:3063 / 3067
页数:5
相关论文
共 5 条
[1]   NONUNIFORMITY OF CANINE LUNG WASHOUT BY HIGH-FREQUENCY VENTILATION [J].
BERDINE, GG ;
LEHR, JL ;
MCKINLEY, DS ;
DRAZEN, JM .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (04) :1388-1394
[2]   GAS DISPERSION IN VOLUME-CYCLED TUBE FLOW .1. THEORY [J].
ELAD, D ;
HALPERN, D ;
GROTBERG, JB .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (01) :312-320
[3]   GAS DISPERSION IN VOLUME-CYCLED TUBE FLOW .2. TRACER BOLUS EXPERIMENTS [J].
GAVER, DP ;
SOLWAY, J ;
PUNJABI, N ;
ELAD, D ;
GROTBERG, JB ;
GAVRIELY, N .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (01) :321-331
[4]  
SOLWAY J, 1982, FED PROC, V41, P1692
[5]   PULSATILE GAS FLOW IN BRONCHI CAUSED BY HEART BEAT [J].
WEST, JB ;
HUGHJONES, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1961, 16 (04) :697-+