QUANTITATION OF DIGITOXIN, DIGOXIN, AND THEIR METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PULSED AMPEROMETRIC DETECTION

被引:20
作者
KELLY, KL
KIMBALL, BA
JOHNSTON, JJ
机构
[1] U.S. Department of Agriculture, Animal and Health Inspection Service, Denver Wildlife Research Center, Denver, CO 80225
关键词
D O I
10.1016/0021-9673(95)00525-R
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel detection method for the cardiac glycosides digitoxin, digoxin, and their metabolites is described. Both isocratic and gradient water-acetonitrile elutions were employed with an octadecylsilane column. The effluent was monitored by integrated pulsed amperometry in an alkaline medium (pH>12) by adding sodium hydroxide post-column. Using isocratic elution, peak responses were linear from 10 to 70 ng, with lower limits of detection between 4 and 15 ng. This method allows easy modification of well-estalished high-performance liquid chromatographic systems, as well as comparable sensitivity and greater selectivity than UV detection.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 30 条
[1]   ISOLATION AND QUANTITATION OF PICOMOLE QUANTITIES OF DIGOXIN, DIGITOXIN AND THEIR METABOLITES BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
CASTLE, MC .
JOURNAL OF CHROMATOGRAPHY, 1975, 115 (02) :437-445
[2]   2-DIMENSIONAL THIN-LAYER CHROMATOGRAPHY OF DIGITALIS CARDENOLIDES USING A CONTINUOUS DEVELOPMENT TECHNIQUE [J].
CLARKE, CJ ;
COBB, PH .
JOURNAL OF CHROMATOGRAPHY, 1979, 168 (02) :541-549
[3]   SEPARATION OF DIGOXIN, DIGITOXIN AND THEIR POTENTIAL METABOLITES, IMPURITIES OR DEGRADATION PRODUCTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DESTA, D ;
KWONG, E ;
MCERLANE, KM .
JOURNAL OF CHROMATOGRAPHY, 1982, 240 (01) :137-143
[4]  
EDWARDS P, 1983, FOOD TECHNOL-CHICAGO, V37, P53
[5]  
EDWARDS P, 1983, AM LAB FAIRFIELD APR, P78
[6]  
EDWARDS R, 1987, TAPPI J, V70, P139
[7]   COMPARISON OF REVERSED-PHASE AND PARTITION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SOME DIGITALIS GLYCOSIDES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1977, 130 (JAN11) :169-180
[8]   SEPARATION OF DIGITALIS GLYCOSIDES BY MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FUJII, Y ;
FUKUDA, H ;
SAITO, Y ;
YAMAZAKI, M .
JOURNAL OF CHROMATOGRAPHY, 1980, 202 (01) :139-143
[9]   POST-COLUMN DERIVATIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AIR SEGMENTATION PRINCIPLE - APPLICATION TO DIGITALIS GLYCOSIDES [J].
GFELLER, JC ;
FREY, G ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV) :271-281
[10]  
HERBRETEAU B, 1992, ANALUSIS, V20, P355