A suitable quantity for evaluating the image quality in mammography is the smallest visible size of an object. This quantity, called the image quality index (IQI), can be derived from the basic image parameters: contrast, MTF, Wiener spectrum. Several evaluation methods of the IQI, all based on statistical decision theory, have been considered. An experimental visibility test using simulated microcalcifications has been performed in order to compare the results obtained with different IQI models. A previous approach, based on simplifying assumptions, yields a good correlation with the visibility test but fails to predict the actual size of the visible objects. Improved models have been derived for an ideal observer and for a 'quasi-ideal' one with perfect or with realistic visual characteristics. The experimental visual results are well modelled by the IQI method, provided that a suitable threshold signal-to-noise ratio is used for each of these models.
引用
收藏
页码:19 / 33
页数:15
相关论文
共 24 条
  • [1] Arfken G., 1970, MATH METHODS PHYS
  • [2] ANALYSIS OF THE DETECTIVE QUANTUM EFFICIENCY OF A RADIOGRAPHIC SCREEN FILM COMBINATION
    BUNCH, PC
    HUFF, KE
    VANMETTER, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05): : 902 - 909
  • [3] CHAN HP, 1985, P SOC PHOTO-OPT INST, V535, P2
  • [4] A METHOD FOR MODULATION TRANSFER-FUNCTION DETERMINATION FROM EDGE PROFILES WITH CORRECTION FOR FINITE-ELEMENT DIFFERENTIATION
    CUNNINGHAM, IA
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1987, 14 (04) : 533 - 537
  • [5] Dainty J. C., 1974, IMAGE SCI
  • [6] DOI K, 1982, RADIOLOGY, V144, P383, DOI 10.1148/radiology.144.2.7089295
  • [7] HARRIS JL, 1965, J OPT SOC AM, V54, P606
  • [8] OBJECTIVE ASSESSMENT OF MAMMOGRAPHY SYSTEMS .2. IMPLEMENTATION
    HESSLER, C
    DEPEURSINGE, C
    GRECESCU, M
    POCHON, Y
    RAIMONDI, S
    VALLEY, JF
    [J]. RADIOLOGY, 1985, 156 (01) : 221 - 225
  • [9] OBJECTIVE ASSESSMENT OF MAMMOGRAPHY SYSTEMS .1. METHOD
    HESSLER, C
    DEPEURSINGE, C
    GRECESCU, M
    POCHON, Y
    RAIMONDI, S
    VALLEY, JF
    [J]. RADIOLOGY, 1985, 156 (01) : 215 - 219
  • [10] DIGITAL IMAGE-PROCESSING - EFFECT ON DETECTABILITY OF SIMULATED LOW-CONTRAST RADIOGRAPHIC PATTERNS
    ISHIDA, M
    DOI, K
    LOO, LN
    METZ, CE
    LEHR, JL
    [J]. RADIOLOGY, 1984, 150 (02) : 569 - 575