SINGLE FLUID INCLUSION ANALYSIS BY LASER ABLATION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY - QUANTIFICATION AND VALIDATION

被引:19
作者
RAMSEY, MH [1 ]
COLES, BJ [1 ]
WILKINSON, JJ [1 ]
RANKIN, AH [1 ]
机构
[1] KINGSTON POLYTECH,SCH GEOL SCI,KINGSTON THAMES KT1 2EE,SURREY,ENGLAND
关键词
LASER ABLATION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; FLUID INCLUSION; CALIBRATION; VALIDATION;
D O I
10.1039/ja9920700587
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation inductively coupled plasma atomic emission spectrometry (ICP-AES) can provide quantitative determinations of element ratios in the concentrated brines contained within single fluid inclusions, larger than 30-mu-m in diameter, in topaz and halite. Inclusions formed at different stages can therefore be analysed separately and differentiated. This is an advantage over previous bulk methods of fluid inclusion analysis by ICP-AES that only provide composite analyses of all inclusion types present. Validation of the laser ablation ICP-AES analyses of the inclusions in topaz was obtained using scanning electron microscopy (qualitative), bulk crush-leach ICP-AES (semiquantitative) and a method of 'geological feasibility' (semi-quantitative). Quantitative validation was achieved using synchrotron X-ray fluorescence microprobe analysis, which showed no significant bias for the determinations of the ratios between Cu, Fe, Mn, Pb and Zn. Synthetic fluid inclusions containing standard solutions were used to validate the laser ablation ICP-AES analysis of inclusions in halite. A bias of <6% was detected for the determinations of ratios between Ba, Ca, K, Li and Mg, and <20% for Sr:Ca. The precision of individual elemental ratios was 20-45% (relative standard deviation) but this could be reduced to 3-8% (standard error on the mean) by the analysis of large numbers of inclusions (e.g., 30). In some natural inclusions the geochemical variability was found to be a limiting factor in the precision of the replicate measurements. The nebulization of standard solutions was found to be an appropriate method of calibration for the determination of element ratios in this application.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 14 条
[1]   ANALYSIS OF FLUID INCLUSIONS USING A PULSED LASER MICRO-PROBE [J].
BENNETT, JN ;
GRANT, JN .
MINERALOGICAL MAGAZINE, 1980, 43 (331) :945-947
[2]   ANALYSIS OF MONO-ATOMIC IONS IN INDIVIDUAL FLUID INCLUSIONS BY LASER-PRODUCED PLASMA EMISSION-SPECTROSCOPY [J].
BOIRON, MC ;
DUBESSY, J ;
ANDRE, N ;
BRIAND, A ;
LACOUR, JL ;
MAUCHIEN, P ;
MERMET, JM .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1991, 55 (03) :917-923
[3]   ATOMIC SPECTROMETRY UPDATE - ENVIRONMENTAL-ANALYSIS [J].
CRESSER, MS ;
ARMSTRONG, J ;
DEAN, J ;
RAMSEY, MH ;
CAVE, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (01) :R1-R67
[5]   CORRELATED VARIANCE IN SIMULTANEOUS INDUCTIVELY COUPLED PLASMA ATOMIC-EMISSION SPECTROMETRY - ITS CAUSES AND CORRECTION BY A PARAMETER-RELATED INTERNAL STANDARD METHOD [J].
RAMSEY, MH ;
THOMPSON, M .
ANALYST, 1985, 110 (05) :519-530
[6]   THE COMPOSITION OF HYPERSALINE, IRON-RICH GRANITIC FLUIDS BASED ON LASER-ICP AND SYNCHROTRON-XRF MICROPROBE ANALYSIS OF INDIVIDUAL FLUID INCLUSIONS IN TOPAZ, MOLE GRANITE, EASTERN AUSTRALIA [J].
RANKIN, AH ;
RAMSEY, MH ;
COLES, B ;
VANLANGEVELDE, F ;
THOMAS, CR .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1992, 56 (01) :67-79
[7]  
RANKIN AH, 1990, IN PRESS 8TH P INT A
[8]   FLUID INCLUSION ANALYSIS - PROLOGUE AND EPILOGUE [J].
ROEDDER, E .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1990, 54 (03) :495-507
[9]  
SHEPHERD TJ, 1985, PRACTICAL GUIDE FLUI, P165
[10]   THE ANALYSIS OF FLUID INCLUSION DECREPITATE BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROSCOPY - AN EXPLORATORY-STUDY [J].
THOMPSON, M ;
RANKIN, AH ;
WALTON, SJ ;
HALLS, C ;
FOO, BN .
CHEMICAL GEOLOGY, 1980, 30 (1-2) :121-133