MULTIDIMENSIONAL GAS-CHROMATOGRAPHY INFRARED SPECTROMETRY MASS-SPECTROMETRY PLENARY LECTURE

被引:10
作者
KROCK, KA [1 ]
RAGUNATHAN, N [1 ]
KLAWUN, C [1 ]
SASAKI, T [1 ]
WILKINS, CL [1 ]
机构
[1] UNIV CALIF RIVERSIDE,DEPT CHEM,RIVERSIDE,CA 92521
关键词
GAS CHROMATOGRAPHY INFRARED SPECTROMETRY MASS SPECTROMETRY; MULTIDIMENSIONAL GAS CHROMATOGRAPHY; COMPLEX MIXTURE ANALYSIS; ESSENTIAL OILS;
D O I
10.1039/an9941900483
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multidimensional gas chromatography coupled with multispectral detection was investigated for the analysis of complex mixtures. As a test of this new methodology, the essential oil of cascarilla bark was analysed by capillary gas chromatography using a combination of mass spectral and both vapour phase and matrix isolation infrared spectral detection. The separation of components in this complex essential oil was carried out using a multidimensional capillary gas chromatography system with parallel cryogenic traps interposed between the first and second separation stages. By employing a multiport valve and multiple traps, it was possible to analyse multiple heartcuts from a single first-stage separation or, alternatively, to concentrate minor components by means of multiple-injection procedures. It was also possible to perform iterative heartcut analysis employing multiple analytical columns with different polarities by sample looping. The instrumentation developed provides flexibility in choice of trapping-time intervals in order to improve dynamic range, reduces experimental time relative to that required with a single cryogenic trap, and facilitates parallel enrichment of minor components in different chromatographic segments. This separation strategy combined with three different modes of spectrometric detection facilitates comprehensive analysis of a complex mixture. In this study, vapour phase and matrix isolation infrared spectral analyses were compared, the advantages of parallel analytical columns for complex mixture analysis were assessed, and a method to fingerprint essential oils by enrichment of minor components was investigated.
引用
收藏
页码:483 / 489
页数:7
相关论文
共 21 条
[1]   QUALITY TEST OF A MECHANICAL SWITCHING VALVE FOR TWO-DIMENSIONAL OPEN TUBULAR GAS-CHROMATOGRAPHY [J].
ADAM, ST .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (01) :85-89
[2]  
Bertsch W., 1978, Journal of High Resolution Chromatography and Chromatography Communications, V1, P289, DOI 10.1002/jhrc.1240010603
[3]  
BERTSCH W, 1990, CHROMATOGRAPHIC SCI, V50, P74
[4]  
BICCHI C, 1989, HRC-J HIGH RES CHROM, V12, P705
[5]   GAS-CHROMATOGRAPHY - MATRIX-ISOLATION - FOURIER TRANSFORM-INFRARED SPECTROMETRY OF NATURAL-PRODUCTS [J].
COLEMAN, WM ;
GORDON, BM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (09) :371-376
[6]   GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED MASS-SPECTROMETRY USING A MASS SELECTIVE DETECTOR [J].
COOPER, JR ;
BOWATER, IC ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2791-2796
[7]   UTILIZATION OF SPECTROMETRIC INFORMATION IN LINKED GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY MASS-SPECTROMETRY [J].
COOPER, JR ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1989, 61 (14) :1571-1577
[8]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[9]  
GORDON BM, 1985, J CHROMATOGR SCI, V23, P1
[10]   COMPONENT ANALYSIS OF EUCALYPTUS OIL BY GAS-CHROMATOGRAPHY FOURIER TRANSFORM-INFRARED SPECTROMETRY MASS-SPECTROMETRY [J].
HEDGES, LM ;
WILKINS, CL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (08) :345-350