IMPACT OF GLUCOSE SELF-MONITORING ON NON-INSULIN-TREATED PATIENTS WITH TYPE-II DIABETES-MELLITUS - RANDOMIZED CONTROLLED TRIAL COMPARING BLOOD AND URINE TESTING

被引:95
作者
ALLEN, BT
DELONG, ER
FEUSSNER, JR
机构
[1] VET ADM MED CTR,HLTH SERV RES & DEV FIELD PROGRAM,508 FULTON ST,DURHAM,NC 27705
[2] VET ADM MED CTR,AMBULATORY CARE SERV,DURHAM,NC 27705
[3] DUKE UNIV,MED CTR,DEPT MED,DURHAM,NC 27710
[4] DUKE UNIV,MED CTR,DEPT COMMUNITY & FAMILY MED,DURHAM,NC 27710
关键词
D O I
10.2337/diacare.13.10.1044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The goal of this study was to compare the relative efficacy and cost of self-monitoring of blood glucose (SMBG) with routine urine testing in the management of patients with type II (non-insulin-dependent) diabetes mellitus not treated with insulin. Fifty-four patients with type II diabetes mellitus, not treated with insulin, who had inadequate glucose control on diet alone or diet and oral hypoglycemic agents were studied. Patients performed SMBG or urine glucose testing as part of a standardized treatment program that also included diet and exercise counseling. During the 6-mo study, both the urine-testing and SMBG groups showed similar improvement in glycemic control; within each group, there were significant improvements in fasting plasma glucose (reduction of 1.4 ± 3.2 mM, P < 0.03) and glycosylated hemoglobin (reduction of 2.0 ± 3.4%, P < 0.01) levels. Seventeen (31%) of 54 patients actually normalized their glycosylated hemoglobin values, 9 in the urine-testing group and 8 in the SMBG group. Comparisons between the urine-testing and SMBG groups showed no significant differences in mean fasting plasma glucose (P > 0.86), glycosylated hemoglobin (P > 0.95), or weight (P > 0.19). In patients with type II diabetes mellitus not treated with insulin, SMBG is no more effective, but is 8-12 times more expensive, than urine testing in facilitating improved glycemic control. Our results do not support widespread use of SMBG in diabetic patients not treated with insulin.
引用
收藏
页码:1044 / 1050
页数:7
相关论文
共 18 条
  • [1] [Anonymous], 1987, DIABETES CARE, V10, P95
  • [2] COMPARATIVE-STUDY OF HOME BLOOD-GLUCOSE MONITORING DEVICES - VISIDEX, CHEMSTRIP BG, GLUCOMETER, AND ACCU-CHEK BG
    AZIZ, S
    HSIANG, YH
    [J]. DIABETES CARE, 1983, 6 (06) : 529 - 532
  • [3] BONHEIM R, 1985, DIABETES FORECAST, V38, P33
  • [4] SELF-MONITORING OF BLOOD-GLUCOSE LEVELS IN NON-INSULIN-DEPENDENT DIABETES-MELLITUS
    COHEN, M
    ZIMMET, P
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1983, 2 (08) : 377 - 380
  • [5] DIETARY FIBER
    CUMMINGS, JH
    [J]. GUT, 1973, 14 (01) : 69 - 81
  • [6] TESTS FOR GLUCOSURIA - AN ANALYSIS OF FACTORS THAT CAUSE MISLEADING RESULTS
    FELDMAN, JM
    LEBOVITZ, FL
    [J]. DIABETES, 1973, 22 (02) : 115 - 121
  • [7] PREVALENCE OF DIABETES AND IMPAIRED GLUCOSE-TOLERANCE AND PLASMA-GLUCOSE LEVELS IN UNITED-STATES POPULATION AGED 20-74 YR
    HARRIS, MI
    HADDEN, WC
    KNOWLER, WC
    BENNETT, PH
    [J]. DIABETES, 1987, 36 (04) : 523 - 534
  • [8] Haynes RB., 1976, COMPLIANCE THERAPEUT, P69
  • [9] SCREENING FOR ORGANIC MENTAL SYNDROMES IN MEDICALLY ILL
    JACOBS, JW
    BERNHARD, MR
    DELGADO, A
    STRAIN, JJ
    [J]. ANNALS OF INTERNAL MEDICINE, 1977, 86 (01) : 40 - 46
  • [10] A CONTROLLED TRIAL ON THE EFFECTS OF PATIENT EDUCATION IN THE TREATMENT OF INSULIN-DEPENDENT DIABETES
    KORHONEN, T
    HUTTUNEN, JK
    ARO, A
    HENTINEN, M
    IHALAINEN, O
    MAJANDER, H
    SIITONEN, O
    UUSITUPA, M
    PYORALA, K
    [J]. DIABETES CARE, 1983, 6 (03) : 256 - 261