LIQUID-NITROGEN COOLING OF MONOCHROMATOR CRYSTALS EXPOSED TO INTENSE SYNCHROTRON RADIATION

被引:14
作者
JOKSCH, S [1 ]
MAROT, G [1 ]
FREUND, A [1 ]
KRISCH, M [1 ]
机构
[1] EUROPEAN SYNCHROTRON RADIAT FASIL,F-38043 GRENOBLE,FRANCE
关键词
D O I
10.1016/0168-9002(91)90345-Q
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using insertion devices as intense light sources in the new, third generation storage rings leads to considerable heat load at the first optical element in the beamline. To minimize the thermal slope of these elements it is proposed to cool them cryogenically. In this article we present first tests of liquid nitrogen cooling of silicon and germanium crystals exposed to high intensity synchrotron radiation. The test were performed with white radiation from the HARWI wiggler at the Hamburger Synchrotronstrahlungslabor (HASYLAB). During the experiment the DORIS ring was running at 3.7 GeV electron energy and up to approximately 100 mA current. The maximum power at the sample surface was approximately 100 W with power densities of up to 0.4 W/mm2. The minimization of thermal deteriorations by cryogenic cooling is demonstrated unambiguously by optical interferometry.
引用
收藏
页码:386 / 390
页数:5
相关论文
共 19 条
[1]  
ARTHUR J, 1990, P WORKSHOP HIGH HEAT, P285
[2]   THE POTENTIAL OF CRYOGENIC SILICON AND GERMANIUM X-RAY MONOCHROMATORS FOR USE WITH LARGE SYNCHROTRON HEAT LOADS [J].
BILDERBACK, DH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :434-436
[3]   UNDULATOR HEAT LOADING STUDIES ON X-RAY MONOCHROMATORS COOLED WITH LIQUID GALLIUM [J].
BILDERBACK, DH ;
HENDERSON, C ;
WHITE, J ;
SMITHER, RK ;
FORSTER, GA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1973-1976
[4]  
FREUND AK, 1990, OPT ENG, V29, P928, DOI 10.1117/12.55678
[5]   HARWI - A HARD X-RAY WIGGLER BEAM AT DORIS [J].
GRAEFF, W ;
BITTNER, L ;
BREFELD, W ;
HAHN, U ;
HEINTZE, G ;
HEUER, J ;
KOUPTSIDIS, J ;
PFLUGER, J ;
SCHWARTZ, M ;
WEINER, EW ;
WROBLEWSKI, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1457-1459
[7]   X-RAY MONOCHROMATORS FOR HIGH-POWER SYNCHROTRON RADIATION SOURCES [J].
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2) :306-311
[8]   SURFACE-TEMPERATURE AND SLOPE ERRORS ON PLANE MIRRORS EXPOSED TO HIGH-POWER SYNCHROTRON RADIATION [J].
JARK, W ;
MOURIKIS, S ;
JOKSCH, S ;
SAILE, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :319-324
[9]   STABILITY OF TUNGSTEN CARBON AND TUNGSTEN SILICON MULTILAYER X-RAY MIRRORS UNDER THERMAL ANNEALING AND X-RADIATION EXPOSURE [J].
KORTRIGHT, JB ;
JOKSCH, S ;
ZIEGLER, E .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (01) :168-174
[10]   OVERVIEW OF THE ADVANCED PHOTON SOURCE [J].
MONCTON, DE ;
CROSBIE, E ;
SHENOY, GK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1403-1405