SYSTEMIC EFFECTS OF HIGH-DOSE INHALED STEROIDS - COMPARISON OF BECLOMETHASONE DIPROPIONATE AND BUDESONIDE IN HEALTHY-SUBJECTS

被引:58
作者
BROWN, PH
MATUSIEWICZ, SP
SHEARING, C
TIBI, L
GREENING, AP
CROMPTON, GK
机构
[1] WESTERN GEN HOSP,DEPT CLIN CHEM,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
[2] ROYAL EDINBURGH & ASSOCIATED HOSP,DEPT CLIN CHEM,EDINBURGH EH3 9HB,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1136/thx.48.10.967
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-Systemic absorption of inhaled corticosteroids may adversely influence the function of the hypothalamo-pituitary-adrenal axis, bone metabolism, and circulating leucocytes. These changes can be used to assess the safety of different types and modes of administration of these drugs. Methods-The study was a randomised, double dummy, crossover design with nine healthy adults. It compared the effects of beclomethasone dipropionate and budesonide (given by metered dose aerosols with and without their respective large volume spacers (Volumatic and Nebuhaler) attached) on serum cortisol, 24 hour urinary free cortisol, and plasma osteocalcin concentrations, and circulating neutrophils and lymphocytes. Subjects inhaled the drug (1 mg) and matching placebo at 0900 and 2200 hours on each of six study days. Blood samples were taken hourly for six hours after the morning dose and at the end of the study period. Results-All results were within the reference ranges. Both drugs caused similar reductions in serum cortisol four to six hours after inhalation. These changes were not affected by the use of a large spacer and did not persist at 24 hours. Use of spacers tended to increase the haematological effects of the steroids. Beclomethasone dipropionate inhaled through a Volumatic provoked a rise in circulating neutrophils compared with placebo although lymphocyte numbers were unaffected. Budesonide did not influence neutrophil numbers but did reduce circulating lymphocytes, numbers of which were further reduced when the Nebuhaler was used. There were no significant changes in plasma osteocalcin concentration or 24 hour urinary free cortisol excretion with budesonide, with or without a spacer. Beclomethasone dipropionate inhaled without a spacer reduced urinary cortisol and plasma osteocalcin at 24 hours; however, use of the Volumatic protected against these effects. Conclusions-Attaching a Volumatic reduces the systemic effects of 2 mg aerosol beclomethasone dipropionate on the hypothalamo-pituitary-adrenal axis and circulating osteocalcin concentrations. This study did not establish whether the Nebuhaler reduces the systemic effects of budesonide. When large spacers are used, 2 mg per day of beclomethasone dipropionate and budesonide seem to be equivalent in terms of unwanted effects.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 33 条
  • [1] BONE TURNOVER DURING HIGH-DOSE INHALED CORTICOSTEROID TREATMENT
    ALI, NJ
    CAPEWELL, S
    WARD, MJ
    [J]. THORAX, 1991, 46 (03) : 160 - 164
  • [2] [Anonymous], 1990, BMJ, V301, P651
  • [3] BROWN JP, 1984, LANCET, V1, P1091
  • [4] LARGE VOLUME SPACER DEVICES AND THE INFLUENCE OF HIGH-DOSE BECLOMETHASONE DIPROPIONATE ON HYPOTHALAMO-PITUITARY-ADRENAL AXIS FUNCTION
    BROWN, PH
    GREENING, AP
    CROMPTON, GK
    [J]. THORAX, 1993, 48 (03) : 233 - 238
  • [5] DO LARGE VOLUME SPACER DEVICES REDUCE THE SYSTEMIC EFFECTS OF HIGH-DOSE INHALED CORTICOSTEROIDS
    BROWN, PH
    BLUNDELL, G
    GREENING, AP
    CROMPTON, GK
    [J]. THORAX, 1990, 45 (10) : 736 - 739
  • [6] HIGH-DOSE INHALED STEROID-THERAPY AND THE CORTISOL STRESS RESPONSE TO ACUTE SEVERE ASTHMA
    BROWN, PH
    BLUNDELL, G
    GREENING, AP
    CROMPTON, GK
    [J]. RESPIRATORY MEDICINE, 1992, 86 (06) : 495 - 497
  • [7] SERUM BONE GLA-PROTEIN COMPARED TO BONE HISTOMORPHOMETRY IN ENDOCRINE DISEASES
    DELMAS, PD
    MALAVAL, L
    ARLOT, ME
    MEUNIER, PJ
    [J]. BONE, 1985, 6 (05) : 339 - 341
  • [8] COMPARISON OF 2 HIGH-DOSE CORTICOSTEROID AEROSOL TREATMENTS, BECLOMETHASONE DIPROPIONATE (1500 UG DAY) AND BUDESONIDE (1600 UG DAY), FOR CHRONIC ASTHMA
    EBDEN, P
    JENKINS, A
    HOUSTON, G
    DAVIES, BH
    [J]. THORAX, 1986, 41 (11) : 869 - 874
  • [9] MORNING SERUM CORTISOL CONCENTRATIONS AFTER 2-MG INHALED BECLOMETHASONE DIPROPIONATE IN NORMAL SUBJECTS - EFFECT OF A 750 ML SPACING DEVICE
    FARRER, M
    FRANCIS, AJ
    PEARCE, SJ
    [J]. THORAX, 1990, 45 (10) : 740 - 742
  • [10] OSTEOCALCIN AND BONE MORPHOMETRIC PARAMETERS IN ADULTS WITHOUT BONE-DISEASE
    GARCIACARRASCO, M
    GRUSON, M
    DEVERNEJOUL, MC
    DENNE, MA
    MIRAVET, L
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1988, 42 (01) : 13 - 17