摘要
Image-guided 31-phosphorus magnetic resonance spectroscopy (MRS) was used to obtain spatially localized 31P spectra of good quality from healthy normal human kidneys and from well-functioning renal allografts. A surface coil of 14 cm diameter was used for acquiring phosphorus signals solely from a volume-of-interest located within the kidney. To determine the effects of kidney transplantation on renal metabolism, patients with well functioning allografts were studied. Little or no phosphocreatine in all spectra verifies the absence of muscle contamination, and is consistent with proper volume localization. The intensity ratio of phosphomonoesters (PME) to adenosine triphosphate (ATP) resonances in transplanted kidneys (PME/ATP = 1.1 ± 0.4) was slightly elevated (P = 0.2) compared to that of healthy normal kidneys (PME/ATP = 0.8 ± 0.3). The inorganic phosphate (Pi) to ATP ratio was similar in the two groups (Pi/ATP = 1.1 ± 0.1 in transplanted kidneys vs. 1.2 ± 0.6 in normal kidneys). Acid/base status, as evidenced from the chemical shift of Pi, was the same in both normal controls and transplanted kidneys. Despite the practical problems produced by organ depth, respiratory movement, and tissue heterogeneity, these results demonstrate that image-guided 31P MR spectra can reliably be obtained from human kidneys.
引用
收藏
页码:294 / 300
页数:7
相关论文
共 51 条
[1]   OBSERVATION OF H-1-NMR SIGNALS WITH RECEIVER COILS TUNED FOR OTHER NUCLIDES [J].
ACKERMAN, JJH ;
GADIAN, DG ;
RADDA, GK ;
WONG, GG .
JOURNAL OF MAGNETIC RESONANCE, 1981, 42 (03) :498-500
[2]   THE ROLE OF INTRA-RENAL PH IN REGULATION OF AMMONIAGENESIS - [P-31] NMR-STUDIES OF THE ISOLATED PERFUSED RAT-KIDNEY [J].
ACKERMAN, JJH ;
LOWRY, M ;
RADDA, GK ;
ROSS, BD ;
WONG, GG .
JOURNAL OF PHYSIOLOGY-LONDON, 1981, 319 (OCT) :65-79
[3]  
AUE WP, 1986, REV MAGN RESON MED, V1, P21
[4]   PHOSPHORUS NUCLEAR MAGNETIC-RESONANCE STUDY OF THE RAT-KIDNEY INVIVO [J].
BALABAN, RS ;
GADIAN, DG ;
RADDA, GK .
KIDNEY INTERNATIONAL, 1981, 20 (05) :575-579
[5]   INVIVO H-1 SPECTROSCOPY IN HUMANS AT 1.5-T [J].
BARANY, M ;
LANGER, BG ;
GLICK, RP ;
VENKATASUBRAMANIAN, PN ;
WILBUR, AC ;
SPIGOS, DG .
RADIOLOGY, 1988, 167 (03) :839-844
[6]   DEPTH-RESOLVED SURFACE-COIL SPECTROSCOPY (DRESS) FOR INVIVO H-1, P-31, AND C-13 NMR [J].
BOTTOMLEY, PA ;
FOSTER, TB ;
DARROW, RD .
JOURNAL OF MAGNETIC RESONANCE, 1984, 59 (02) :338-342
[7]  
BOTTOMLEY PA, 1989, RADIOLOGY, V170, P1
[8]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[9]  
CHAN L, 1981, ORGAN PRESERVATION, V3, P113
[10]  
CHAN L, 1982, ACUTE RENAL FAILURE, P35