EFFECTS OF A FINITE-SIZED PINHOLE ON 3D IMAGE-FORMATION IN CONFOCAL 2-PHOTON FLUORESCENCE MICROSCOPY

被引:30
作者
GU, M
SHEPPARD, CJR
机构
[1] Department of Physical Optics, University of Sydney, NSW
基金
澳大利亚研究理事会;
关键词
D O I
10.1080/09500349314552011
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We investigate three-dimensional (3D) imaging properties in confocal two-photon (2-p) fluorescence microscopy with a finite-sized detector. The 3D intensity point spread function, the 3D optical transfer function (OTF), the strength of optical sectioning and the signal levels for point, planar and volume objects are calculated in order to reveal their relationships to the detector size. It is shown that confocal 2-p fluorescence imaging with a point detector gives superresolution, compared with conventional 2-p imaging without a confocal pinhole. Although optical sectioning can be attained in the latter case, its strength is inferior to that in the confocal case. In particular, a finite-sized detector can result in negative values in the 3D OTF and reduce the effective cut-off spatial frequencies, thus degrading the capability of confocal 2-p fluorescence microscopy for 3D imaging. Unlike the single-photon fluorescence microscope, there is no missing cone of spatial frequencies in the 3D OTF for confocal 2-p fluorescence imaging when the detector size becomes very large
引用
收藏
页码:2009 / 2024
页数:16
相关论文
共 15 条
[1]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[2]   OPTICAL TRANSFER OF 3-DIMENSIONAL OBJECT [J].
FRIEDEN, BR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (01) :56-&
[3]   2ND-HARMONIC IMAGING IN SCANNING OPTICAL MICROSCOPE [J].
GANNAWAY, JN ;
SHEPPARD, CJR .
OPTICAL AND QUANTUM ELECTRONICS, 1978, 10 (05) :435-439
[4]   CONFOCAL FLUORESCENT MICROSCOPY WITH A FINITE-SIZED CIRCULAR DETECTOR [J].
GU, M ;
SHEPPARD, CJR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (01) :151-153
[5]  
GU M, 1991, OPTIK, V89, P65
[6]  
NAKAMURA O, 1993, OPTIK, V93, P39
[7]   APPROXIMATION TO THE THREE-DIMENSIONAL OPTICAL TRANSFER-FUNCTION [J].
SHEPPARD, CJR ;
GU, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1991, 8 (04) :692-694
[8]   RESONANT SCANNING OPTICAL MICROSCOPE [J].
SHEPPARD, CJR ;
KOMPFNER, R .
APPLIED OPTICS, 1978, 17 (18) :2879-2882
[9]  
SHEPPARD CJR, 1977, IEEE J QUANTUM ELECT, V13, pD100
[10]  
SHEPPARD CJR, 1990, OPTIK, V86, P104