EVALUATION OF A PHOTODIODE ARRAY DETECTOR FOR THE VERIFICATION OF PEAK HOMOGENEITY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:8
作者
CHAN, HK
CARR, GP
机构
[1] Wyeth Research, Maidenhead, Berkshire SL6 0PH, Huntercombe Lane South
关键词
HPLC; peak homogeneity; pharmaceutical analysis; Photodiode array detectors;
D O I
10.1016/0731-7085(90)80036-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capable of detecting inhomogeneities at low levels. In this paper, a test has been devised to challenge the sensitivity of instruments to this application. The test makes use of mixtures of the similar benzodiazepines temazepam and lormetazepam in a chromatographic system which does not separate them. One instrument has demonstrated the ability to detect levels of just 0.5% w/w of one benzodiazepine in the other. Statistical F-tests and t-tests have been used to demonstrate that non-homogeneities have been detected with a high level of confidence. It is concluded that photodiode array detectors have the potential to evaluate the homogeneity of chromatographic peaks with a high degree of sensitivity. However, most instruments do not realize this potential because their software does not make proper use of all the data available. © 1990.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 12 条
[1]   RECENT DEVELOPMENTS IN MULTICHANNEL, PHOTODIODE-ARRAY, OPTICAL LC DETECTION [J].
ALFREDSON, T ;
SHEEHAN, T .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (11) :473-482
[2]  
ALFREDSON T, 1985, AM LAB, V17, P40
[3]   DETERMINATION OF COMPOUND IDENTITY BY GROUP TYPE AND CLASS USING DIODE-ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALFREDSON, T ;
SHEEHAN, T ;
LENERT, T ;
AAMODT, S ;
CORREIA, L .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :213-223
[4]   PEAK HOMOGENEITY DETERMINATION FOR THE VALIDATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY-METHODS [J].
CARTER, GT ;
SCHIESSWOHL, RE ;
BURKE, H ;
YANG, R .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1982, 71 (03) :317-321
[5]   RAPID-SCANNING, MULTI-CHANNEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION OF ZIMELDINE AND METABOLITES WITH 3-DIMENSIONAL GRAPHICS AND CONTOUR PLOTTING [J].
CLARK, BJ ;
FELL, AF ;
SCOTT, HP ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1984, 286 (MAR) :261-273
[6]   DUAL-WAVELENGTH ABSORBANCE RATIO FOR SOLUTE RECOGNITION IN LIQUID-CHROMATOGRAPHY [J].
DROUEN, ACJH ;
BILLIET, HAH ;
DEGALAN, L .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :971-978
[7]   NOVEL TECHNIQUES FOR PEAK RECOGNITION AND DECONVOLUTION BY COMPUTER-AIDED PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :123-140
[8]   APPLICATIONS OF RAPID-SCANNING MULTICHANNEL DETECTORS IN CHROMATOGRAPHY - PLENARY LECTURE [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (01) :3-17
[9]   NUMERICAL SPECTROSCOPY - ABSORBANCE INDEX TECHNIQUE AND ALGORITHM FOR QUALITATIVE-ANALYSIS IN LIQUID-CHROMATOGRAPHY [J].
POILE, AF ;
CONLON, RD .
JOURNAL OF CHROMATOGRAPHY, 1981, 204 (JAN) :149-152
[10]   LIMITATION OF ASSESSING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC PEAK PURITY WITH PHOTODIODE ARRAY DETECTORS [J].
SCHIEFFER, GW .