FLOW CYTOMETRIC DNA ANALYSIS OF CORNEAL EPITHELIUM

被引:5
作者
BURNS, ER
ROBERSON, MC
BROWN, MF
SHOCK, JP
PIPKIN, JL
HINSON, WG
ANSON, JF
机构
[1] NATL CTR TOXICOL RES,DIV GENET TOXICOL,JEFFERSON,AR 72079
[2] UNIV ARKANSAS MED SCI HOSP,DEPT OPHTHALMOL,LITTLE ROCK,AR 72205
来源
AMERICAN JOURNAL OF ANATOMY | 1990年 / 187卷 / 03期
关键词
D O I
10.1002/aja.1001870305
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
We have modified an existing technique in order to perform DNA analysi by flow cytometry (FCM) of corneal epithelium from the mouse, rat, chicken, rabbit, and human. This protocol permitted an investigation of human corneal scrapings from several categories: normal, aphakic bullous keratopathy (ABK), keratoconus (KC), Fuch's dystrophy, edema, epithelial dysplasia, and lipid degeneration. No abnormal characteristic cell‐kinetic profile was detected when averaged DNA histograms were compared statsitically between the normal and either ABK, KC, edema, or Fuch's dystrophy groups. Abnormal DNA histograms were recorded for cell samples that were taken (1) from three individuals who had epithelial dysplasia and (2) from one individual diagnosed with lipid degeneration. The former condition was characterized by histograms that had a subpopulation of cells with an aneuploid amont of DNA or had higher than normal percentages of cells in the S and G2 + M phases of the cell cycle. Corneal cells from the patient who had lipid degeneration had an abnormally high percentage of cells in the G2 + M phases of the cell cycle. The availability of accurate DNA flow cytometric analysis of corneal epithelium allows further studies on this issue from both experimental and clinical situations. Copyright © 1990 Wiley‐Liss, Inc.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 10 条
[1]   NONPARAMETRIC FLOW CYTOMETRY ANALYSIS [J].
BAGWELL, CB ;
HUDSON, JL ;
IRVIN, GL .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :293-296
[2]   PREPARATION AND STABILITY OF 16 MURINE TISSUES AND ORGANS FOR FLOW CYTOMETRIC CELL-CYCLE ANALYSIS [J].
BURNS, ER ;
BAGWELL, CB ;
HINSON, WG ;
PIPKIN, JL ;
HUDSON, JL .
CYTOMETRY, 1983, 4 (02) :150-160
[3]   CIRCADIAN-RHYTHM IN MITOTIC INDEX OF CORNEAL EPITHELIUM - PRESENCE OF EHRLICH ASCITES-CARCINOMA AND TREATMENT WITH SALINE OR HYDROXYUREA [J].
BURNS, ER .
ANATOMICAL RECORD, 1981, 199 (04) :491-505
[4]   ISOPROTERENOL-INDUCED PHASE-SHIFTS IN CIRCADIAN-RHYTHM OF MITOSIS IN MURINE CORNEAL EPITHELIUM [J].
BURNS, ER ;
SCHEVING, LE .
JOURNAL OF CELL BIOLOGY, 1973, 56 (02) :605-608
[5]   CIRCADIAN INFLUENCE ON WAVE FORM OF FREQUENCY OF LABELED MITOSES IN MOUSE CORNEAL EPITHELIUM [J].
BURNS, ER ;
SCHEVING, LE .
CELL AND TISSUE KINETICS, 1975, 8 (01) :61-66
[6]   APPLICATION OF DNA FLOW-CYTOMETRY TO PARAFFIN-EMBEDDED ARCHIVAL MATERIAL FOR THE STUDY OF ANEUPLOIDY AND ITS CLINICAL-SIGNIFICANCE [J].
HEDLEY, DW ;
FRIEDLANDER, ML ;
TAYLOR, IW .
CYTOMETRY, 1985, 6 (04) :327-333
[7]   FLOW CYTOMETRIC DETERMINATION OF DNA PLOIDY LEVEL IN NUCLEI ISOLATED FROM PARAFFIN-EMBEDDED TISSUE [J].
SCHUTTE, B ;
REYNDERS, MMJ ;
BOSMAN, FT ;
BLIJHAM, GH .
CYTOMETRY, 1985, 6 (01) :26-30
[8]   TECHNICAL AND STATISTICAL IMPROVEMENTS FOR FLOW CYTOMETRIC DNA ANALYSIS OF PARAFFIN-EMBEDDED TISSUE [J].
SICKLESANTANELLO, BJ ;
FARRAR, WB ;
DECENZO, JF ;
KEYHANIROFAGHA, S ;
KLEIN, J ;
PEARL, D ;
LAUFMAN, H ;
OTOOLE, RV .
CYTOMETRY, 1988, 9 (06) :594-599
[9]   MODIFICATION OF A TRYPSIN-DETERGENT METHOD FOR DNA FLOW-CYTOMETRY OF HUMAN-EPIDERMIS [J].
STOUGH, DB ;
BURNS, ER ;
MALLORY, SB ;
PIPKIN, JL ;
HINSON, WG .
CYTOMETRY, 1989, 10 (01) :90-93
[10]   A DETERGENT-TRYPSIN METHOD FOR THE PREPARATION OF NUCLEI FOR FLOW CYTOMETRIC DNA ANALYSIS [J].
VINDELOV, LL ;
CHRISTENSEN, IJ ;
NISSEN, NI .
CYTOMETRY, 1983, 3 (05) :323-327