REPRODUCIBILITY OF NONINVASIVE ULTRASONIC MEASUREMENT OF CAROTID ATHEROSCLEROSIS - THE ASYMPTOMATIC CAROTID-ARTERY PLAQUE STUDY

被引:190
作者
RILEY, WA
BARNES, RW
APPLEGATE, WB
DEMPSEY, R
HARTWELL, T
DAVIS, VG
BOND, MG
FURBERG, CD
机构
[1] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,DEPT NEUROBIOL & ANAT,WINSTON SALEM,NC 27103
[2] RES TRIANGLE INST,RES TRIANGLE PK,NC 27709
[3] UNIV TENNESSEE CTR HLTH SCI,DEPT PREVENT MED,MEMPHIS,TN 38163
[4] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,DEPT PUBL HLTH SCI,WINSTON SALEM,NC 27103
[5] UNIV KENTUCKY,DIV NEUROSURG,LEXINGTON,KY 40506
关键词
CAROTID ARTERY DISEASES; CLINICAL TRIALS; ULTRASONICS;
D O I
10.1161/01.STR.23.8.1062
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose: To determine the effect of a lipid-lowering agent and/or a low-dose antithrombotic agent on the progression of early-stage carotid atherosclerosis, noninvasive B-mode ultrasound was used to measure intimal-medial thickness in asymptomatic individuals with moderately elevated lipids as part of the ongoing multicenter Asymptomatic Carotid Artery Plaque Study. Methods: Uniform ultrasonic scanning and reading protocols were implemented to obtain maximum intimal-medial thickness measurements in 12 standard segments in patients having a small to moderate wall thickness (1.5-3.5 mm) in at least one of the carotid arteries. Paired B-mode image recordings on 858 patients, performed 1 month apart and read at a core laboratory (each pair by the same reader), determined both within-sonographer (W, n=405) and between-sonographer (B, n=453) reproducibility. Results: The primary end point (mean+/-SD), defined in each individual as the mean value of the 12 maximum intimal-medial thickness measurements, was 1.31+/-0.21 mm (W) and 1.32+/-0.22 (B) at the time of the second examination. The mean difference in the primary end point (exam 2-exam 1) was -0.01+/-0.13 mm (W) and 0.00+/-0.15 mm (B). The Pearson correlation coefficients were 0.79 (W) and 0.75 (B). In 90% of the patients, the absolute difference in the primary end point was <0.22 mm (W) and <0.24 mm (B). Variability of the secondary end point, defined as the single largest intimal-medial thickness measurement in a patient, was between three and four times larger than the variability for the primary end point. Differences in sonographer performance between clinical centers were very small. Conclusions. The results demonstrate that standardized noninvasive ultrasonic techniques yield highly reproducible measures of carotid intimal-medial thickness, which can serve as a measure of carotid atherosclerosis in clinical trials that monitor small rates of lesion progression.
引用
收藏
页码:1062 / 1068
页数:7
相关论文
共 17 条
  • [1] [Anonymous], 1991, J Neuroimaging, V1, P68
  • [2] [Anonymous], AM J EPIDEMIOL
  • [3] ARMSTRONG ML, 1989, PATHOBIOLOGY HUMAN A, P469
  • [4] BOND MG, 1989, AM J MED, V86, P33
  • [5] BOND MG, 1990, J CARDIOVASC PHARM, V15, pS30
  • [6] BOND MG, 1989, ATHEROSCLEROSIS, V8, P637
  • [7] EVALUATION OF A SCORING SYSTEM FOR EXTRACRANIAL CAROTID ATHEROSCLEROSIS EXTENT WITH B-MODE ULTRASOUND
    CROUSE, JR
    HARPOLD, GH
    KAHL, FR
    TOOLE, JF
    MCKINNEY, WM
    [J]. STROKE, 1986, 17 (02) : 270 - 275
  • [8] Fried Linda P., 1991, Annals of Epidemiology, V1, P263
  • [9] COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES
    GLAGOV, S
    WEISENBERG, E
    ZARINS, CK
    STANKUNAVICIUS, R
    KOLETTIS, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) : 1371 - 1375
  • [10] GOSTOMZYK JG, 1988, KLIN WOCHENSCHR, V66, P58