MALDISTRIBUTION OF THE CEREBRAL BLOOD-FLOW IN RETROGRADE CEREBRAL PERFUSION

被引:11
作者
FUKAE, K
NAKASHIMA, A
HISAHARA, M
KAWACHI, Y
MASUDA, M
YASUI, H
机构
[1] Divimon of Cardiovascular Surgery, Research Institute of Angiocardiology, Kyushu University, Fukuoka, 812, 3-1-1 Maldashi, Higashi-ku
关键词
RETROGRADE CEREBRAL PERFUSION; CEREBRAL TISSUE BLOOD FLOW; HYDROGEN CLEARANCE METHOD; LASER DOPPLER FLOWMETER; AORTIC ARCH OPERATION;
D O I
10.1016/S1010-7940(95)80049-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Retrograde cerebral perfusion (RCP) through a superior vena caval (SVC) cannula has now become a useful alternative for brain protection during aortic arch operations, However, little is still known about its physiological effects, especially regarding the flow distribution in the brain, We studied the cerebral blood flow distribution under hypothermic conditions using mongrel dogs (n=6, weighing 9.5 to 14 kg), We measured the cerebral tissue blood flow of the cortex with a laser Doppler flowmeter and the cerebral tissue blood flow of the medulla using the hydrogen clearance method, The cerebral blood flow distribution at 28 degrees C with a whole body bypass flow of 100 ml/kg per min and aortic pressure of 88.3 +/- 20.4 mmHg was used as a control, Then the body temperature was decreased to 20 degrees C and the descending aorta was cross-clamped just distal to the origin of the left subclavian artery to establish antegrade cerebral perfusion (ACP), The perfusion flow was decreased to 54.8 +/- 12.4 ml/kg per min so as to make the aortic pressure similar to the control conditions, After measuring the cerebral blood flow distribution in ACP, the perfusion was then switched to RCP through the bilateral internal maxillary vein and the SVC pressure was kept at 40 mmHg, In RCP, the cerebral blood flow of the medulla was quite similar to that in ACP (12.4 ml/min per 100 g versus 15.2 ml/min per 100 g, NS), In contrast, the cerebral blood flow of the cortex significantly decreased to 16% of the flow in ACP (7.8 perfusion units versus 50 perfusion units, P < 0.01), Because of the maldistribution of the cerebral blood flow in RCP, careful attention should be paid to the clinical application of this method.
引用
收藏
页码:496 / 501
页数:6
相关论文
共 15 条
[1]  
Cooly D.A., Surgical treatment of the transverse aortic arch: Experience with 25 patients using hypothermic techniques, Ann Thorac Surg, 32, pp. 260-272, (1981)
[2]  
Crawford E., Surgical treatment of aneurysm and/or dissection of the ascending aorta, transverse aortic arch, and ascending aorta and transverse aortic arch: Factors influencing survival in 717 patients, J Thorac Cardiovasc Surg, 98, pp. 659-674, (1989)
[3]  
Ergin M.A., Hypothermic circulatory arrest in operations on the thoracic aorta, J Thorac Cardiovasc Surg, 107, pp. 788-799, (1994)
[4]  
Hegedus S.A., A comparative anatomical study of the cranio-cervical venous systems in mammals, with special reference to the dog: Relationship of anatomy to measurements of cerebral blood flow, Am J Anat, 116, pp. 375-386, (1965)
[5]  
Lass J., Advances in Aortic Arch Surgery Ann Thorac Surg, 53, pp. 227-232, (1992)
[6]  
Lemole G.M., Improved results for dissecting aneurysms: Intraluminal sutureless prosthesis, J Thorac Cardiovasc Surg, 83, pp. 249-255, (1982)
[7]  
Miles N.L., Massive air embolism during cardiopulmonary bypass: Causes, prevention, and management, J Thorac Cardiovasc Surg, 80, pp. 708-718, (1980)
[8]  
Pasztor E., The hydrogen clearance method in assessment of blood flow in cortex, white matter and deep nuclei of baboons, Stroke, 4, pp. 556-567, (1973)
[9]  
Safi H.J., Brain protection via cerebral retrograde perfusion during aortic arch aneurysm repair, Ann Thorac Surg, 56, pp. 270-276, (1993)
[10]  
Stern M.D., Continuous measurement of tissue blood flow by laser-Doppler spectroscopy, Am J Physiol, 232, pp. H441-H448, (1977)