COMPARISON OF RINGERS ACETATE WITH 3-PERCENT DEXTRAN-70 FOR VOLUME LOADING BEFORE EXTRADURAL CESAREAN-SECTION

被引:20
作者
WENNBERG, E
FRID, I
HALJAMAE, H
WENNERGREN, M
KJELLMER, I
机构
[1] GOTHENBURG UNIV,SAHLGRENS HOSP,DEPT OBSTET & GYNAECOL,S-41345 GOTHENBURG,SWEDEN
[2] GOTHENBURG UNIV,SAHLGRENS HOSP,DEPT PEDIAT,S-41345 GOTHENBURG,SWEDEN
关键词
Anaesthesia; obstetric: Caesarean section; Anaesthetic techniques: extradural; Fluid balance: volume loading; colloid; crystalloid;
D O I
10.1093/bja/65.5.654
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have studied haemodilution and cardiovascular responses to i.v. hydration with either 3% dextran 70 (D×70) or Ringer's acetate using a non-invasive cardiac output monitor (BoMed NCCOM3-R7) in 40 healthy parturients undergoing Caesarean section under extradural anaesthesia. Haemodilution was more pronounced, and central venous pressure, mean arterial pressure and cardiac index maintained at greater values, after treatment with D×70. Colloid osmotic pressures (COP) decreased by 1.7 mm Hg after loading with 3% D×70, and by 5.6 mm Hg in mothers treated with Ringer's acetate (P < 0.001). The transthoracic fluid index decreased more after hydration with Ringer's acetate (P < 0.001), indicating an increase in lung water. In spite of these maternal changes, there were no differences in neonatal bioimpedance or values of haemoglobin, PCV, albumin and COP in umbilical cord blood, and only one case of respiratory distress. We conclude that colloids may be preferable to crystalloids for circulatory preload for extradural Caesarean section, as greater haemodynamic stability was maintained and increases in lung water avoided. © 1990 British Journal of Anaesthesia.
引用
收藏
页码:654 / 660
页数:7
相关论文
共 21 条
[1]  
ANTOINE C, 1982, AM J OBSTET GYNECOL, V142, P55
[2]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[3]   COLLOID OSMOMETER FOR SMALL FLUID SAMPLES [J].
AUKLAND, K ;
JOHNSEN, HM .
ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 90 (02) :485-490
[4]  
BRIZGYS RV, 1987, ANESTHESIOLOGY, V67, P782
[5]   SPINAL-ANESTHESIA FOR CESAREAN-SECTION - THE INFLUENCE OF HYPOTENSION ON NEONATAL OUTCOME [J].
CORKE, BC ;
DATTA, S ;
OSTHEIMER, GW ;
WEISS, JB ;
ALPER, MH .
ANAESTHESIA, 1982, 37 (06) :658-662
[6]   EFFECTS OF MATERNAL POSITION ON EPIDURAL-ANESTHESIA FOR CESAREAN-SECTION, ACID-BASE STATUS, AND BUPIVACAINE CONCENTRATIONS AT DELIVERY [J].
DATTA, S ;
ALPER, MH ;
OSTHEIMER, GW ;
BROWN, WU ;
WEISS, JB .
ANESTHESIOLOGY, 1979, 50 (03) :205-209
[7]  
ESPEJO MGA, 1989, CRIT CARE MED, V17, P360
[8]   HYPOTENSION DURING EPIDURAL-ANESTHESIA FOR CESAREAN-SECTION - A COMPARISON OF INTRAVENOUS LOADING WITH CRYSTALLOID AND COLLOID SOLUTIONS [J].
HALLWORTH, D ;
JELLICOE, JA ;
WILKES, RG .
ANAESTHESIA, 1982, 37 (01) :53-56
[9]  
HEDIN H, 1982, INT ARCH ALLER A IMM, V68, P122, DOI 10.1159/000233080
[10]   EPIDEMIOLOGIC ANALYSIS OF THE INCREASED RISK OF DISTURBED NEONATAL RESPIRATORY ADAPTATION AFTER CESAREAN-SECTION [J].
KRANTZ, ME ;
WENNERGREN, M ;
BENGTSON, LGW ;
HJALMARSON, O ;
KARLSSON, K ;
SELLGREN, U .
ACTA PAEDIATRICA SCANDINAVICA, 1986, 75 (05) :832-839