COMPARISON OF TRANSTHORACIC AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR DETECTION OF ABNORMALITIES OF PROSTHETIC AND BIOPROSTHETIC VALVES IN THE MITRAL AND AORTIC POSITIONS

被引:176
作者
DANIEL, WG
MUGGE, A
GROTE, J
HAUSMANN, D
NIKUTTA, P
LAAS, J
LICHTLEN, PR
MARTIN, RP
机构
[1] HANNOVER MED SCH,DEPT THORAC & CARDIOVASC SURG,DIV CARDIOL,W-3000 HANNOVER,GERMANY
[2] EMORY UNIV,SCH MED,DIV CARDIOL,ATLANTA,GA 30322
关键词
D O I
10.1016/0002-9149(93)90740-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional echocardiography is the diagnostic procedure of choice for evaluation of prosthetic valve abnormalities. However, transthoracic echocardiography (TTE) may be limited owing to acoustic shadowing and poor acoustic windows. Some of these limitations may be over. come by transesophageal echocardiography (TEE). One hundred twenty-six patients with 148 Prosthetic valves (113 bioprostheses and 35 mechanical devices) were studied by M-mode and 2-dimensional TTE and TEE. Prosthetic valve morphology was confirmed by surgery or autopsy in all cases; 124 prostheses were classified as diseased (33 endocarditis, 8 thrombi, and 83 degeneration defined as leaflet thickening >3 mm with restricted motion) and 24 as normal. Prosthetic valve endocarditis and thrombi were correctly identified by TTE in 12 of 33 (36%) and 1 of a (13%) Prostheses, respectively, but could be diagnosed by TEE in 27 of 33 (82%; p < 0.001) and 8 of 8 (100%; p < 0.01), respectively, compared with TTE, TEE had a higher sensitivity for logic prosthetic valve abnormalities in patients with either bioprostheses (88 [87%] vs 66 [65%] of 101 prostheses; p < 0.01) or mechanical devices (19 [83%] vs 5 [22%] of 23 prostheses; p < 0.01) and in patients with a prosthesis in either the aortic (49 [77%] vs 32 [50%] of 64; p < 0.01) or mitral (58 [97%] vs 39 [65%] of 60; p < 0.001) position. Overall, sensitivity and specificity were 57 and 63%, respectively, for TTE, and 86 and 88%, respectively, for TEE. TEE is superior to TTE in the correct identification of morphologic prosthetic valve abnormalities, and should be used in patients with suspected prosthetic valve malfunction and negative TTE.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 28 条
  • [1] DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES
    ALAM, M
    ROSMAN, HS
    LAKIER, JB
    KEMP, S
    KHAJA, F
    HAUTAMAKI, K
    MAGILLIGAN, DJ
    STEIN, PD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) : 851 - 858
  • [2] ECHO-PHONOCARDIOGRAPHIC EVALUATION OF THE BJORK-SHILEY MITRAL PROSTHESIS
    ASSANELLI, D
    AQUILINA, M
    MARANGONI, S
    MORGAGNI, GL
    VISIOLI, O
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (01) : 165 - 170
  • [3] THROMBOSIS OF A BJORK-SHILEY AORTIC-VALVE PROSTHESIS DIAGNOSED BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    BOSKOVIC, D
    PECHACEK, LW
    KRAJCER, Z
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1983, 11 (03) : 165 - 169
  • [4] DOPPLER ECHOCARDIOGRAPHIC APPEARANCE OF CUSP TEARS IN TISSUE VALVE PROSTHESES
    CHAMBERS, JB
    MONAGHAN, MJ
    JACKSON, G
    JEWITT, DE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (02) : 462 - 466
  • [5] EVALUATION OF NORMAL PROSTHETIC VALVE FUNCTION BY DOPPLER ECHOCARDIOGRAPHY
    COOPER, DM
    STEWART, WJ
    SCHIAVONE, WA
    LOMBARDO, HP
    LYTLE, BW
    LOOP, FD
    SALCEDO, EE
    [J]. AMERICAN HEART JOURNAL, 1987, 114 (03) : 576 - 582
  • [6] CUNHA CLP, 1980, MAYO CLIN PROC, V55, P231
  • [7] Daniel L B, 1990, Echocardiography, V7, P83, DOI 10.1111/j.1540-8175.1990.tb00352.x
  • [8] SAFETY OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY - A MULTICENTER SURVEY OF 10,419 EXAMINATIONS
    DANIEL, WG
    ERBEL, R
    KASPER, W
    VISSER, CA
    ENGBERDING, R
    SUTHERLAND, GR
    GRUBE, E
    HANRATH, P
    MAISCH, B
    DENNIG, K
    SCHARTL, M
    KREMER, P
    ANGERMANN, C
    ILICETO, S
    CURTIUS, JM
    MUGGE, A
    [J]. CIRCULATION, 1991, 83 (03) : 817 - 821
  • [9] IMPROVEMENT IN THE DIAGNOSIS OF ABSCESSES ASSOCIATED WITH ENDOCARDITIS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    DANIEL, WG
    MUGGE, A
    MARTIN, RP
    LINDERT, O
    HAUSMANN, D
    NONNASTDANIEL, B
    LAAS, J
    LICHTLEN, PR
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (12) : 795 - 800
  • [10] DANIEL WG, 1989, TRANSESOPHAGEAL ECHO, P354