LEFT-VENTRICULAR MASS QUANTITATION USING SINGLE-PHASE CARDIAC MAGNETIC-RESONANCE-IMAGING

被引:16
作者
AURIGEMMA, G
DAVIDOFF, A
SILVER, K
BOEHMER, J
SERIO, A
PATTISON, N
机构
[1] CENT MASSACHUSETTS MAGNET IMAGING CTR,WORCESTER,MA
[2] UNIV MASSACHUSETTS,MED CTR,DEPT MED,DIV CARDIOVASC,WORCESTER,MA 01655
[3] UNIV MASSACHUSETTS,MED CTR,DEPT RADIOL,WORCESTER,MA 01655
关键词
D O I
10.1016/0002-9149(92)91285-C
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been used to measure left ventricular (LV) mass in animals with superior accuracy. However, its use in cardiac patients has been limited by the long total scan times necessitated by imaging the heart at end-diastole at each of 8 to 10 slice locations. Recent canine studies showed that LV mass may be determined accurately, with considerable timesavings, by use of sequential images throughout the cardiac cycle (single-phase MRI). Twenty normal subjects underwent spin-echo MRI to determine the relationship between LV mass computed from single-phase MRI and results obtained from the more time-consuming end-diastolic MRI (which was used as the reference standard for this study). The left ventricle was spanned with 2 interleaved series of 5 short-axis 1 cm thick slices. 5 images, evenly spaced throughout the cardiac cycle, were obtained at each slice location in all subjects. LV mass ranged from 86 to 198 g. Although end-diastolic LV mass exceeded single-phase results by an average of 5 g (p <0.002), there was a close correlation between the 2 (slope = 0.99; r = 0.96). Although LV mass derived from end-diastolic images exceeded single-phase results, this difference is unlikely to be clinically significant and is small compared with the standard error of echocardiographic methods. Furthermore, when the order in which single-phase images were selected was reversed, there was improved agreement with end-diastolic MRI. Thus, the close correlation between single-phase and end-diastolic results indicates that single-phase MRI may be a practical, time-efficient method to determine LV mass in humans with normal LV shape.
引用
收藏
页码:259 / 262
页数:4
相关论文
共 17 条
  • [1] AURIGEMMA G, 1991, American Journal of Cardiac Imaging, V5, P257
  • [2] MEASUREMENT OF CANINE LEFT-VENTRICULAR MASS BY USING MR IMAGING
    CAPUTO, GR
    TSCHOLAKOFF, D
    SECHTEM, U
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) : 33 - 38
  • [3] VALUE OF ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR MASS IN PREDICTING CARDIOVASCULAR MORBID EVENTS IN HYPERTENSIVE MEN
    CASALE, PN
    DEVEREUX, RB
    MILNER, M
    ZULLO, G
    HARSHFIELD, GA
    PICKERING, TG
    LARAGH, JH
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (02) : 173 - 178
  • [4] CIRCUMFERENTIAL MYOCARDIAL SHORTENING IN THE NORMAL HUMAN LEFT-VENTRICLE - ASSESSMENT BY MAGNETIC-RESONANCE-IMAGING USING SPATIAL MODULATION OF MAGNETIZATION
    CLARK, NR
    REICHEK, N
    BERGEY, P
    HOFFMAN, EA
    BROWNSON, D
    PALMON, L
    AXEL, L
    [J]. CIRCULATION, 1991, 84 (01) : 67 - 74
  • [5] ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD
    DEVEREUX, RB
    REICHEK, N
    [J]. CIRCULATION, 1977, 55 (04) : 613 - 618
  • [6] MEASUREMENT OF LEFT-VENTRICULAR MASS INVIVO USING GATED NUCLEAR-MAGNETIC-RESONANCE IMAGING
    FLORENTINE, MS
    GROSSKREUTZ, CL
    CHANG, W
    HARTNETT, JA
    DUNN, VD
    EHRHARDT, JC
    FLEAGLE, SR
    COLLINS, SM
    MARCUS, ML
    SKORTON, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) : 107 - 112
  • [7] EFFECT OF ACUTE CHANGES IN CORONARY BLOOD-FLOW ON LEFT-VENTRICULAR END-DIASTOLIC WALL THICKNESS - ECHOCARDIOGRAPHIC STUDY
    GAASCH, WH
    BERNARD, SA
    [J]. CIRCULATION, 1977, 56 (04) : 593 - 598
  • [8] MASS OF LEFT-VENTRICULAR MYOCARDIUM ESTIMATED WITH DYNAMIC SPATIAL RECONSTRUCTOR
    IWASAKI, T
    SINAK, LJ
    HOFFMAN, EA
    ROBB, RA
    HARRIS, LD
    BAHN, RC
    RITMAN, EL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (01): : H138 - H142
  • [9] ESTIMATION OF HUMAN MYOCARDIAL MASS WITH MR IMAGING
    KATZ, J
    MILLIKEN, MC
    STRAYGUNDERSEN, J
    BUJA, LM
    PARKEY, RW
    MITCHELL, JH
    PESHOCK, RM
    [J]. RADIOLOGY, 1988, 169 (02) : 495 - 498
  • [10] INVIVO MEASUREMENT OF MYOCARDIAL MASS USING NUCLEAR-MAGNETIC-RESONANCE IMAGING
    KELLER, AM
    PESHOCK, RM
    MALLOY, CR
    BUJA, LM
    NUNNALLY, R
    PARKEY, RW
    WILLERSON, JT
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) : 113 - 117