THE APPLICATION OF CORRELATED SAMPLING TO THE COMPUTATION OF ELECTRON-BEAM DOSE DISTRIBUTIONS IN HETEROGENEOUS PHANTOMS USING THE MONTE-CARLO METHOD

被引:17
作者
HOLMES, MA [1 ]
MACKIE, TR [1 ]
SOHN, W [1 ]
RECKWERDT, PJ [1 ]
KINSELLA, TJ [1 ]
BIELAJEW, AF [1 ]
ROGERS, DWO [1 ]
机构
[1] NATL RES COUNCIL CANADA,OTTAWA K1A 0R6,ONTARIO,CANADA
关键词
D O I
10.1088/0031-9155/38/6/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the Monte Carlo method is capable of computing the dose distribution in heterogeneous phantoms directly, there am some advantages to computing a heterogeneity correction factor. If this approach is adopted there are savings in time using correlated sampling. This technique forces histories to have the same energy, position, direction and random number seed as incident on both the heterogeneous and homogeneous water phantom. This ensures that a history that has, by chance, travelled through only water in the heterogeneous phantom will have the same path as it would have through the homogeneous phantom, resulting in a reduced variance when a ratio of heterogeneous dose to homogeneous dose is formed. Metrics to describe the distributions of uncertainty, efficiency, and degree of correlation am defined. EGS4 Monte Carlo calculation of the dose distribution from a 20 MeV electron beam on water phantoms containing aluminium or air slab heterogeneities illustrate that this technique is the most efficient when the heterogeneity is deep within the phantom, but that improved efficiency can be realized even when the heterogeneity is at or near the surface. This is because some correlation between the two histories is retained despite passage through the heterogeneity.
引用
收藏
页码:675 / 688
页数:14
相关论文
共 11 条
[1]  
ANDRE L, 1990, 1990 JAHR TAG DGMP S
[2]   INFLUENCE OF ENERGY AND ANGULAR SPREAD ON STOPPING-POWER RATIOS FOR ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A ;
NAHUM, A ;
MATTSSON, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :751-768
[3]   STOPPING-POWER RATIOS AND THEIR UNCERTAINTIES FOR CLINICAL ELECTRON-BEAM DOSIMETRY [J].
ANDREO, P ;
FRANSSON, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1847-1861
[4]   A STANDARD TIMING BENCHMARK FOR EGS4 MONTE-CARLO CALCULATIONS [J].
BIELAJEW, AF ;
ROGERS, DWO .
MEDICAL PHYSICS, 1992, 19 (02) :303-304
[5]   ELECTRON DEPTH DOSE DEPENDENCE ON ENERGY SPECTRAL QUALITY [J].
JOHNSEN, SW ;
LARIVIERE, PD ;
TANABE, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (12) :1401-1407
[6]  
MA C, 1992, THESIS PHYSICS DEP L
[7]  
Nelson W. R., 1985, EGS4 CODE SYSTEM SLA
[8]  
ROGERS DWO, 1990, DOSIMETRY IONIZING R, V3, P407
[9]  
TENG SP, 1987, NUCL SCI J, V24, P247