CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE

被引:34
作者
MATAR, FA [1 ]
MINTZ, GS [1 ]
DOUEK, P [1 ]
FARB, A [1 ]
VIRMANI, R [1 ]
JAVIER, SP [1 ]
POPMA, JJ [1 ]
PICHARD, AD [1 ]
KENT, KM [1 ]
SATLER, LF [1 ]
KELLER, M [1 ]
LEON, MB [1 ]
机构
[1] WASHINGTON HOSP CTR,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20010
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 33卷 / 03期
关键词
ATHEROSCLEROSIS; COMPUTERIZED IMAGING; CORONARY ARTERY DISEASE; INTRAVASCULAR ULTRASOUND; 3-DIMENSIONAL IMAGING;
D O I
10.1002/ccd.1810330305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To validate an automated algorithm for the measurement of lumen volumes of coronary arteries. Background: Current intravascular ultrasound systems use absolute measurements of and changes in areas and diameters for the assessment of coronary artery disease. However, the coronary artery is a three-dimensional structure of complex geometry and volume. Methods: We used a comprehensive imaging system designed to reconstruct planar intravascular ultrasound images in three dimensions. This system consisted of a 25 MHz transducer-tipped rigid probe (for in vitro studies) or a 25 MHz transducer-tipped catheter within a 3.9F monorail imaging sheath (for in vivo studies), a motorized catheter pullback device that withdrew the transducer at 0.5 mm/sec, and an image processing computer that stacked 15 image slices/mm of vessel axial length and then performed thresholding-based three dimensional image rendering and lumen volume measurement. We imaged 13 human coronary vessels (6 RCA, 6 LAD, 1 LCX) in vitro and 16 vessels (8 LAD, 6 RCA, 2 SVG) in vivo. Results: In vitro studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 171 +/- 121 mm(3) acid compared very well with those derived by histology (160 +/- 109 mm(3), r = 0.97, SEE = 29 mm(3), P < 0.001) and with those derived by manual planimetry of planar intravascular ultrasound images (150 +/- 106 mm(3), r = 0.97, SEE = 30 mm(3), P < 0.001). In vivo studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 74 +/- 35 mm(3) and compared well with those derived by quantitative angiography (52 +/- 20 mm(3), r = 0.71, SEE = 25 mm(3), P < 0.002). Conclusions: Three-dimensional intravascular ultrasound is a new technique that can accurately measure coronary artery lumen volumes. Further technical improvements may help to establish this technique as the new standard for lumen volume measurement. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 14 条
  • [1] ARTERIOGRAPHIC ASSESSMENT OF CORONARY ATHEROSCLEROSIS - REVIEW OF CURRENT METHODS, THEIR LIMITATIONS, AND CLINICAL-APPLICATIONS
    BROWN, BG
    BOLSON, EL
    DODGE, HT
    [J]. ARTERIOSCLEROSIS, 1982, 2 (01): : 2 - 15
  • [2] NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING
    CHO, ZH
    MUN, CW
    FRIEDENBERG, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) : 134 - 143
  • [3] INVITRO VALIDATION OF 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND FOR THE EVALUATION OF ARTERIAL INJURY AFTER BALLOON ANGIOPLASTY
    COY, KM
    PARK, JC
    FISHBEIN, MC
    LAAS, T
    DIAMOND, GA
    ADLER, L
    MAURER, G
    SIEGEL, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 692 - 700
  • [4] QUANTITATIVE CORONARY ANGIOGRAPHY TO MEASURE PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS - VALUE, LIMITATIONS, AND IMPLICATIONS FOR CLINICAL-TRIALS
    DEFEYTER, PJ
    SERRUYS, PW
    DAVIES, MJ
    RICHARDSON, P
    LUBSEN, J
    OLIVER, MF
    [J]. CIRCULATION, 1991, 84 (01) : 412 - 423
  • [5] 3-DIMENSIONAL IMAGING
    FISHMAN, EK
    MAGID, D
    NEY, DR
    CHANEY, EL
    PIZER, SM
    ROSENMAN, JG
    LEVIN, DN
    VANNIER, MW
    KUHLMAN, JE
    ROBERTSON, DD
    [J]. RADIOLOGY, 1991, 181 (02) : 321 - 337
  • [6] COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES
    GLAGOV, S
    WEISENBERG, E
    ZARINS, CK
    STANKUNAVICIUS, R
    KOLETTIS, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) : 1371 - 1375
  • [7] ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY
    GUSSENHOVEN, EJ
    ESSED, CE
    LANCEE, CT
    MASTIK, F
    FRIETMAN, P
    VANEGMOND, FC
    REIBER, J
    BOSCH, H
    VANURK, H
    ROELANDT, J
    BOM, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 947 - 952
  • [8] IDENTIFICATION AND 3-D QUANTIFICATION OF ATHEROSCLEROSIS USING MAGNETIC-RESONANCE IMAGING
    MERICKEL, MB
    CARMAN, CS
    BROOKEMAN, JR
    MUGLER, JP
    BROWN, MF
    AYERS, CR
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 1988, 18 (02) : 89 - 102
  • [9] INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION
    NISHIMURA, RA
    EDWARDS, WD
    WARNES, CA
    REEDER, GS
    HOLMES, DR
    TAJIK, AJ
    YOCK, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) : 145 - 154
  • [10] CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND
    POTKIN, BN
    BARTORELLI, AL
    GESSERT, JM
    NEVILLE, RF
    ALMAGOR, Y
    ROBERTS, WC
    LEON, MB
    [J]. CIRCULATION, 1990, 81 (05) : 1575 - 1585