A bolus injection of Gadopentetate Dimeglumine with dynamic gradient echo MR imaging has allowed for the visualization of normal and abnormal renal function. Following an injection of gadopentetate dimeglumine, NMR T1 relaxation times obtained on serial collections of serum and urine at timed intervals were used to derive the glomerular filtration rate. The merger of dynamic contrast‐enhanced MRI with an in vitro NMR‐derived GFR provides for assessment of renal function without the use of radioactive agents. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:319 / 323
页数:5
相关论文
共 10 条
[1]   MEASUREMENT OF GLOMERULAR-FILTRATION RATE IN MAN USING DTPA-TC-99M [J].
BIANCHI, C ;
BONADIO, M ;
DONADIO, C ;
TRAMONTI, G ;
FIGUS, S .
NEPHRON, 1979, 24 (04) :174-178
[2]   USE OF GD-DTPA AND FAST GRADIENT-ECHO AND SPIN-ECHO MR IMAGING TO DEMONSTRATE RENAL-FUNCTION IN THE RABBIT [J].
CARVLIN, MJ ;
ARGER, PH ;
KUNDEL, HL ;
AXEL, L ;
DOUGHERTY, L ;
KASSAB, EA ;
MOORE, B .
RADIOLOGY, 1989, 170 (03) :705-711
[3]   DYNAMIC GD-DTPA - ENHANCED MR IMAGING OF THE KIDNEY - EXPERIMENTAL RESULTS [J].
CHOYKE, PL ;
FRANK, JA ;
GIRTON, ME ;
INSCOE, SW ;
CARVLIN, MJ ;
BLACK, JL ;
AUSTIN, HA ;
DWYER, AJ .
RADIOLOGY, 1989, 170 (03) :713-720
[4]  
CHOYKE PL, 1990, 9TH ANN M SOC MAGN R, V2, P775
[5]  
Daly P F, 1989, Am J Physiol Imaging, V4, P165
[6]   GADOLINIUM-DTPA ENHANCED DYNAMIC MR IMAGING IN THE EVALUATION OF CISPLATINUM NEPHROTOXICITY [J].
FRANK, JA ;
CHOYKE, PL ;
GIRTON, ME ;
AUSTIN, HA ;
SIEVENPIPER, C ;
INSCOE, SW ;
BLACK, JL ;
CARVLIN, MJ ;
DWYER, AJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) :448-459
[7]   GADOPENTETATE DIMEGLUMINE CLEARANCE IN RENAL-INSUFFICIENCY IN RABBITS [J].
FRANK, JA ;
CHOYKE, PL ;
GIRTON, ME ;
MORRISON, P ;
DIGGS, R ;
SKINNER, M .
INVESTIGATIVE RADIOLOGY, 1990, 25 (11) :1212-1216
[8]   NORMAL AND HYDRONEPHROTIC KIDNEY - EVALUATION OF RENAL-FUNCTION WITH CONTRAST-ENHANCED MR IMAGING [J].
KIKINIS, R ;
VONSCHULTHESS, GK ;
JAGER, P ;
DURR, R ;
BINO, M ;
KUONI, W ;
KUBLER, O .
RADIOLOGY, 1987, 165 (03) :837-842
[9]   MEASUREMENT OF RENAL-FUNCTION IN CHRONIC RENAL-DISEASE [J].
LEVEY, AS .
KIDNEY INTERNATIONAL, 1990, 38 (01) :167-184
[10]   OBSTRUCTIVE NEPHROPATHY - EVALUATION WITH DYNAMIC GD-DTPA ENHANCED MR IMAGING [J].
SEMELKA, RC ;
HRICAK, H ;
TOMEI, E ;
FLOTH, A ;
STOLLER, M .
RADIOLOGY, 1990, 175 (03) :797-803