THERMAL-ENERGY STORES FOR SUPPLYING DOMESTIC HOT-WATER AND SPACE-HEATING

被引:9
作者
CHAUVET, LP
PROBERT, SD
NEVRALA, DJ
机构
[1] CRANFIELD UNIV,DEPT APPL ENERGY,BEDFORD MK43 OAL,ENGLAND
[2] BRITISH GAS PLC,GLOBAL GAS,LONDON W1A 2AZ,ENGLAND
关键词
D O I
10.1016/0306-2619(94)90022-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Factors influencing the ability of a conventional domestic hot-water tank to deliver domestic hot water rapidly have been culled, collated or assessed experimentally. It has been deduced that, with a horizontal-axis coiled, finned-type, heat exchanger-immersed in the traditional domestic hot-water tank-for extracting heat from the tank NuBAR (+/-0.04) = 0.28 Ra0.29 for 100 < Ra < 1500 where NuBAR and Ra are the mean Nusselt and Rayleigh numbers, respectively, for the freely-convecting flow in the tank. Among the design conclusions are: (i) The optimal value of the ratio of 'height-to-diameter.for the thermal store lies between 3 and 4. This is a compromise between achieving the improvements associated with (a) having a high degree of stratification (e.g. resulting from the use of a tall tank) and so facilitating rapid heat removal, and (b) minimising the surface area (and hence the rate ok wild heat loss from the store). (ii) Preferably, the walls of the thermal store should be made of a low-thermal-conductivity material and, provided mechanical integrity can be assured, only be of small thickness, thereby enhancing the degree of stratification achieved in the store. (iii) An approximate value for the optimal thickness of thermal insulant applied to the tank, in order to minimise the wild heat losses through the tank's walls, can be calculated. Thus, for a typical insulant, it is recommended that a thickness of more than three times that traditionally used on domestic hot-water tanks be applied. (iv) The use of a horizontal plate, located near the middle of the store, can lead to small increases in the rate of useful heat recovery from the store.
引用
收藏
页码:163 / 190
页数:28
相关论文
共 25 条
  • [1] INFLUENCES OF BAFFLES ON THE RATE OF HEAT-RECOVERY VIA A FINNED-TUBE HEAT-EXCHANGER IMMERSED IN A HOT-WATER STORE
    CHAUVET, LP
    NEVRALA, DJ
    PROBERT, SD
    [J]. APPLIED ENERGY, 1993, 45 (03) : 191 - 217
  • [2] HEAT-TRANSFER CORRELATIONS FOR AN IMMERSED FINNED HEAT-EXCHANGER COIL TRANSFERRING HEAT FROM A HOT-WATER STORE
    CHAUVET, LP
    NEVRALA, DJ
    PROBERT, SD
    [J]. APPLIED ENERGY, 1993, 44 (04) : 283 - 314
  • [3] COLE RL, 1982, ASHRAE T, V88, P1005
  • [4] COLLARD C, 1990, THESIS CRANFIELD I T
  • [5] ECKERT ERG, 1959, HEAT MASS TRANSFER, pA7502
  • [6] EDWARDS JA, ASME62WA205 PAP
  • [7] FEIEREISEN TJ, 1982, ASME82 WASOL18 PAP
  • [8] LOW RAYLEIGH NUMBER NATURAL-CONVECTION HEAT-TRANSFER FROM HIGH-TEMPERATURE HORIZONTAL WIRES TO GASES
    HESSE, G
    SPARROW, EM
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1974, 17 (07) : 796 - 798
  • [9] KERN DQ, 1972, EXTENDED SURFACE HEA, P102
  • [10] KNUDSEN JG, 1965, CHEM ENG PROGR S SER, V61, P44